Riser Card
2
1
Slot
Location Code/Comments
2
10-90
PCI Primary
1
10-B0
PCI Secondary, short card only
SCSI Bus Termination
The Model B50 has an Ultra SCSI bus which can support internal and external SCSI
devices. However, each controller on these SCSI busses must have a unique SCSI
ID. The external SCSI busses must be properly terminated to ensure SCSI signal
integrity.
For directions on setting the SCSI ID on each device, consult the documentation for
that device, as well as the Adapters, Devices, and Cable Information for Multiple Bus
Systems.
Note: Internal SCSI IDs cannot be used on the external SCSI connector (J38). The
internal SCSI IDs are as follows:
SCSI ID
Internal Device
2
Upper Hard-Disk Drive
3
CD-ROM Drive
4
Lower Hard-Disk Drive
Chapter 1. Reference Information
1-9