Step 1540-4
One of the FRUs remaining in the server is defective.
1. Turn off the power.
2. Exchange one of the FRUs in the following list:
System board (see note 3 on page 2-1).
Memory module
3. Turn on the power.
Note: You are asked questions regarding the operator panel display. You are
also asked to perform certain actions based on displayed POST
indicators. Please be observant of these conditions.
Does the operator panel do one of the following:
Stop with any code other than E1DC, E1F2, E1F3, E1F7 or E14D?
Alternate between E1FD and any other code?
NO
Go to
"
MAP 0410: Repair Checkout
"
in the Diagnostics Information for
Multiple Bus Systems.
YES
Reinstall the original FRU.
Repeat the FRU replacement steps until the defective FRU is identified or
all the FRUs have been exchanged.
If the symptom did not change and all the FRUs have been exchanged,
call your service support person for assistance.
If the symptom has changed, check for loose cards, cables, and obvious
problems. If you do not find a problem, return to “Step 1540-1” on
page 2-18, and follow the instructions for the new symptom.
2-20
7046 Model B50 Service Guide
All manuals and user guides at all-guides.com
Summary of Contents for RS/6000 7046 B50
Page 2: ...All manuals and user guides at all guides com...
Page 8: ...vi 7046 Model B50 Service Guide All manuals and user guides at all guides com...
Page 30: ...1 12 7046 Model B50 Service Guide All manuals and user guides at all guides com...
Page 94: ...3 30 7046 Model B50 Service Guide All manuals and user guides at all guides com...
Page 100: ...4 6 7046 Model B50 Service Guide All manuals and user guides at all guides com...
Page 190: ...A 6 7046 Model B50 Service Guide All manuals and user guides at all guides com...
Page 194: ...X 4 7046 Model B50 Service Guide All manuals and user guides at all guides com...
Page 197: ...All manuals and user guides at all guides com...