Step 1540-5
No failure was detected with this configuration.
1. Turn off the power.
2. Install a memory module.
3. Turn on the power.
Does the operator panel do one of the following:
Stop with any code other than E1DC, E1F2, E1F3, E1F7 or E14D?
Alternate between E1FD and any other code?
NO
Repeat this step until all the memory modules are installed and tested.
After all the memory modules are installed and tested, go to “Step
1540-8” on page 2-22.
YES
Go to “Step 1540-6”
Step 1540-6
The failure may be caused by the last memory module installed. To isolate the
failing FRU, do the following:
1. Turn off the power.
2. Exchange the last memory module installed.
3. Turn on the power.
Does the operator panel do one of the following:
Stop with any code other than E1DC, E1F2, E1F3, E1F7 or E14D?
Alternate between E1FD and any other code?
NO
Go to
"
MAP 0410: Repair Checkout
"
in the Diagnostics Information for
Multiple Bus Systems.
YES
Go to “Step 1540-7” on page 2-22.
Chapter 2. Maintenance Analysis Procedures (MAPs)
2-21
All manuals and user guides at all-guides.com
all-guides.com
Summary of Contents for RS/6000 7046 B50
Page 2: ...All manuals and user guides at all guides com...
Page 8: ...vi 7046 Model B50 Service Guide All manuals and user guides at all guides com...
Page 30: ...1 12 7046 Model B50 Service Guide All manuals and user guides at all guides com...
Page 94: ...3 30 7046 Model B50 Service Guide All manuals and user guides at all guides com...
Page 100: ...4 6 7046 Model B50 Service Guide All manuals and user guides at all guides com...
Page 190: ...A 6 7046 Model B50 Service Guide All manuals and user guides at all guides com...
Page 194: ...X 4 7046 Model B50 Service Guide All manuals and user guides at all guides com...
Page 197: ...All manuals and user guides at all guides com...