Boot Problems or Concerns
Depending on the boot device, a checkpoint may be displayed on the operator panel
for an extended period of time while the boot image is retrieved from the device.
This is particularly true for Tape and Network boot attempts. If booting from
CD-ROM or Tape, watch for activity on the drive's LED indicator. A blinking LED
indicates that the loading of either the boot image or additional information required
by the operating system being booted is still in progress. If the checkpoint is
displayed for an extended period of time and the drive LED is not indicating any
activity, there may be a problem loading the boot image from the device.
Note: For network boot attempts, if the system is not connected to an active
network or if the target server is inaccessible (this can also result from
incorrect IP parameters being supplied), the system will still attempt to boot.
Because time-out durations are necessarily long to accommodate retries, the
system may appear to be hung.
This section assumes that a CD-ROM drive is installed and a Diagnostics CD-ROM
is available.
1. Restart the system and get to the Firmware SMS Main Menu. Select Multiboot.
Check if the intended boot device is correctly specified in the boot sequence.
Verify that a boot image resides on the media of the specified boot devices.
– Unload any removable (ie. Diskette, CD-ROM, or Tape) media that can
not be verified.
– If the intended boot device is not correctly identified in the boot
sequence, add it to the boot sequence using the SMS menus. If the
intended boot device cannot be added to the boot sequence go to step
3.
– If attempting to boot from the network go to step 2.
– If attempting to boot from a disk drive or CD-ROM go to step 3.
2. If attempting to boot from the network:
Verify that IP parameters are correct.
Attempt to "Ping" the target server using the SMS Ping utility. If the ping is
successful, have the network administrator verify the server configuration for
this client.
Turn power Off, then On and retry the boot operation.
Check the network cabling to adapter.
3. Try to boot and run standalone diagnostics against the system, particularly
against the intended boot device.
Chapter 3. Error Code to FRU Index
3-27
All manuals and user guides at all-guides.com
all-guides.com
Summary of Contents for RS/6000 7046 B50
Page 2: ...All manuals and user guides at all guides com...
Page 8: ...vi 7046 Model B50 Service Guide All manuals and user guides at all guides com...
Page 30: ...1 12 7046 Model B50 Service Guide All manuals and user guides at all guides com...
Page 94: ...3 30 7046 Model B50 Service Guide All manuals and user guides at all guides com...
Page 100: ...4 6 7046 Model B50 Service Guide All manuals and user guides at all guides com...
Page 190: ...A 6 7046 Model B50 Service Guide All manuals and user guides at all guides com...
Page 194: ...X 4 7046 Model B50 Service Guide All manuals and user guides at all guides com...
Page 197: ...All manuals and user guides at all guides com...