If the intended boot device is not listed in the NEW RESOURCE list, go to
"
MAP 0290: Missing Resource Problem Resolution
"
in Diagnostics
Information for Multiple Bus Systems.
If an SRN, not an 8-digit error code, is reported, go to Diagnostics
Information for Multiple Bus Systems.
If the diagnostics are successful, it may be necessary to perform an
operating system-specific recovery process, or reinstall the operating system.
If unable to load standalone diagnostics:
a. Verify that the SCSI bus is properly terminated.
b. Check the SCSI cabling.
c. It is possible that another attached SCSI device is causing the problem.
– Disconnect the signal and power cables from any other SCSI devices
attached to the SCSI adapter that the CD-ROM drive is attached to.
– Try to boot the standalone diagnostics again.
– If unable to load standalone diagnostics, go to step 4.
– If standalone diagnostics load, one of the disconnected devices is
causing the problem, reconnect the devices one at a time. Retry the
boot operation until the problem recurs and replace the device that
caused the problem. If the problem appears to be one of the SCSI
devices, be aware it could be either the SCSI device or the SCSI
adapter. Go to
"
MAP 0410: Repair Checkout
"
in Diagnostics
Information for Multiple Bus Systems.
4. It is possible that another installed adapter is causing the problem.
Remove all installed adapters except the one the CD-ROM drive is attached
to and the one used for the console.
Try to boot the standalone diagnostics again.
If unable to load standalone diagnostics, go to step 5.
If standalone diagnostics load, reinstall adapters (and attached devices as
applicable) one at a time. Retry the boot operation until the problem recurs.
Then replace the adapter or device that caused the problem (the system
board can also cause the device or adapter to fail). Go to
"
MAP 0410:
Repair Checkout
"
in Diagnostics Information for Multiple Bus Systems.
5. Either the CD-ROM drive, SCSI adapter, the graphics adapter, or the system
board is most likely defective. A tty terminal attached to serial port 1 also can be
used to determine if the graphics adapter is causing the problem. This is done
by removing the graphics adapter, attaching a tty terminal to serial port 1, and
retrying standalone diagnostics. If the standalone diagnostics load, replace the
graphics adapter.
If the CD-ROM drive is attached to a SCSI adapter card rather than the
integrated SCSI adapter on the system board:
– Replace the SCSI adapter.
– Replace the riser card.
3-28
7046 Model B50 Service Guide
All manuals and user guides at all-guides.com
Summary of Contents for RS/6000 7046 B50
Page 2: ...All manuals and user guides at all guides com...
Page 8: ...vi 7046 Model B50 Service Guide All manuals and user guides at all guides com...
Page 30: ...1 12 7046 Model B50 Service Guide All manuals and user guides at all guides com...
Page 94: ...3 30 7046 Model B50 Service Guide All manuals and user guides at all guides com...
Page 100: ...4 6 7046 Model B50 Service Guide All manuals and user guides at all guides com...
Page 190: ...A 6 7046 Model B50 Service Guide All manuals and user guides at all guides com...
Page 194: ...X 4 7046 Model B50 Service Guide All manuals and user guides at all guides com...
Page 197: ...All manuals and user guides at all guides com...