SPCN
Error
Codes
Attention:
If
a
power
supply
or
fan
is
hot-swapped,
wait
five
minutes,
then
recheck
the
AIX
error
log.
If
the
system
has
to
be
shut
down
to
replace
a
power
supply
or
fan,
reboot
the
system,
wait
five
minutes
after
the
AIX
login
prompt
appears,
then
recheck
the
AIX
error
log.
If
the
detailed
information
for
the
most
recent
error
with
the
same
identifier
indicates
that
the
original
problem
has
not
been
fixed
by
performing
the
first
action
in
the
action
column,
continue
with
the
next
action
in
the
action
column.
Attention:
If
you
replace
FRUs
or
perform
an
action
and
the
problem
is
still
not
corrected,
go
to
“MAP
1540:
Minimum
Configuration”
on
page
110
unless
otherwise
indicated
in
the
tables.
If
you
replace
FRUs
and
the
problem
is
corrected,
go
to
″
MAP
0410:
Repair
Checkout
″
in
RS/6000
and
Eserver
pSeries
Diagnostic
Information
for
Multiple
Bus
Systems
.
Note:
Do
not
shut
down
the
system
if
the
FRU
was
replaced
by
hot
swap.
Table
5.
SPCN
Error
Codes
Error
Code
Description
Action/
Possible
Failing
FRU
1011
00AC
ac
loss
or
brownout
detected
Information
message
1011
00EF
Room
emergency
power
off
detected
Information
message
1011
1510
Power
supply
1
power
source
failure
1.
Check
input
power
to
power
supply
1
Location:
U0.1-V1
2.
Primary
I/O
drawer
power
supply
1
Location:
U0.1-V1
3.
Primary
I/O
backplane
Location:
U0.1-P1
1011
1511
Power
supply
1
fault
1.
Primary
I/O
drawer
power
supply
1
Location:
U0.1-V1
2.
Primary
I/O
backplane
Location:
U0.1-P1
1011
1512
Power
supply
1
non-power
fault
1.
Primary
I/O
drawer
power
supply
1
Location:
U0.1-V1
2.
Primary
I/O
backplane
Location:
U0.1-P1
1011
1513
Power
supply
1
domain
fault
1.
Primary
I/O
drawer
power
supply
1
Location:
U0.1-V1
2.
Primary
I/O
backplane
Location:
U0.1-P1
1011
1514
Power
supply
1
cooling
fault
1.
Primary
I/O
drawer
power
supply
1
Location:
U0.1-V1
2.
Primary
I/O
backplane
Location:
U0.1-P1
1011
1516
Swapped
power
supply
and
cooling
unit
or
power
supply
1
missing
1.
Verify
correct
installation
of
power
supply
and
cooling
unit
Location:
U0.1-V1
2.
Primary
I/O
power
supply
1
Location:
U0.1-V1
1011
1520
Power
supply
2
power
source
failure
1.
Check
input
power
to
Power
Supply
2
Location:
U0.1-V2
2.
Primary
I/O
drawer
power
supply
2
Location:
U0.1-V2
3.
Primary
I/O
backplane
Location:
U0.1-P1
Chapter
5.
Error
Code
to
FRU
Index
165
Summary of Contents for RS/6000 Enterprise Server M80
Page 1: ...RS 6000 Enterprise Server Model M80 Eserver pSeries 660 Model 6M1 Service Guide SA38 0571 01...
Page 10: ...x Service Guide...
Page 14: ...xiv Service Guide...
Page 16: ...xvi Service Guide...
Page 22: ...Data Flow 4 Service Guide...
Page 30: ...CEC Card Cage Rear of CEC drawer viewed from top cover removed 12 Service Guide...
Page 84: ...66 Service Guide...
Page 176: ...158 Service Guide...
Page 376: ...358 Service Guide...
Page 430: ...412 Service Guide...
Page 485: ...Chapter 11 Parts Information This chapter contains parts information for the system 467...
Page 486: ...CEC Drawer Card Assembly 9 468 Service Guide...
Page 488: ...CEC Drawer Backplane 5 2a 1 2 3 4 470 Service Guide...
Page 490: ...CEC Drawer Power Supplies 1 2 3 4 5 6 7 8 9 472 Service Guide...
Page 492: ...CEC Drawer Fan Assemblies 2 1 3 4 5 6 8 9 10 11 12 13 7 14 474 Service Guide...
Page 496: ...7 8 9 10 6 1 2 3 4 4 5 478 Service Guide...
Page 508: ...490 Service Guide...
Page 520: ...502 Service Guide...
Page 522: ...504 Service Guide...
Page 526: ...508 Service Guide...
Page 558: ...540 Service Guide...
Page 565: ......