Table
5.
SPCN
Error
Codes
(continued)
Error
Code
Description
Action/
Possible
Failing
FRU
1031
840F
I/O
type
not
recognized
1.
Check
cabling
2.
From
the
main
service
processor
menu,
select
the
System
Information
Menu
,
then
select
the
Power
Control
Network
Utilities
Menu
.
Use
option
three
to
set
the
I/O
type
to
84.
Reboot
the
system.
3.
Primary
I/O
drawer
backplane
Location:
U0.1-P1
1031
8A00
A
different
I/O
drawer
is
connected
to
the
CEC
Informational
only
1031
9012
Invalid
address
1.
Check
SPCN
cabling
2.
Secondary
I/O
backplane
Location:
U0.3-P1
1031
9013
Invalid
address
1.
Check
SPCN
cabling
2.
Secondary
I/O
backplane
Location:
U0.3-P1
1031
9014
Invalid
address
mode
Update
system
firmware
Location:
U0.1-P1/Y1
Note:
Allow
up
to
30
minutes
for
this
update
to
take
effect.
1031
9021
SPCN
temporary
internal
error
Information
only
1031
9022
Secondary
I/O
drawer
not
present
Check
cabling
1031
9023
Secondary
I/O
drawer
is
present
but
off
Information
only
1031
902D
Secondary
I/O
drawer
not
present
Information
only
1031
9038
I/O
drawer
node
fault
Secondary
I/O
backplane
Location:
U0.3-P1
1031
9039
I/O
drawer
node
fault
Secondary
I/O
backplane
Location:
U0.3-P1
1031
9042
EEPROM
failure
Secondary
I/O
backplane
Location:
U0.3-P1
1031
9043
Download
failure
1.
Check
for
system
firmware
update
2.
Call
second
level
of
support
1031
9046
QDS
packet
sequence
error
1.
Check
for
system
firmware
update
2.
Call
second
level
of
support
1031
9047
QDS
block
sequence
error
1.
Check
for
system
firmware
update
2.
Call
second
level
of
support
1031
9080
Undefined
status
code
received
Secondary
I/O
backplane
Location:
U0.3-P1
1031
90F0
Drawer
not
present
in
configuration
table
1.
Check
SPCN
cabling
2.
Reset
system
and
reboot
3.
Secondary
I/O
backplane
Location:
U0.3-P1
1031
90F1
Drawer
added
to
configuration
table
Information
only
1031
9102
Permanent
address
assignment
failed
Secondary
I/O
backplane
Location:
U0.3-P1
1031
9109
Download
failure
Secondary
I/O
backplane
Location:
U0.3-P1
186
Service
Guide
Summary of Contents for RS/6000 Enterprise Server M80
Page 1: ...RS 6000 Enterprise Server Model M80 Eserver pSeries 660 Model 6M1 Service Guide SA38 0571 01...
Page 10: ...x Service Guide...
Page 14: ...xiv Service Guide...
Page 16: ...xvi Service Guide...
Page 22: ...Data Flow 4 Service Guide...
Page 30: ...CEC Card Cage Rear of CEC drawer viewed from top cover removed 12 Service Guide...
Page 84: ...66 Service Guide...
Page 176: ...158 Service Guide...
Page 376: ...358 Service Guide...
Page 430: ...412 Service Guide...
Page 485: ...Chapter 11 Parts Information This chapter contains parts information for the system 467...
Page 486: ...CEC Drawer Card Assembly 9 468 Service Guide...
Page 488: ...CEC Drawer Backplane 5 2a 1 2 3 4 470 Service Guide...
Page 490: ...CEC Drawer Power Supplies 1 2 3 4 5 6 7 8 9 472 Service Guide...
Page 492: ...CEC Drawer Fan Assemblies 2 1 3 4 5 6 8 9 10 11 12 13 7 14 474 Service Guide...
Page 496: ...7 8 9 10 6 1 2 3 4 4 5 478 Service Guide...
Page 508: ...490 Service Guide...
Page 520: ...502 Service Guide...
Page 522: ...504 Service Guide...
Page 526: ...508 Service Guide...
Page 558: ...540 Service Guide...
Page 565: ......