Table
7.
Service
Processor
Error
Codes
(continued)
Error
Code
Description
Action/
Possible
Failing
FRU
406A
00B7
Self
test
detected
insufficient
hardware
resources
to
continue
IPL
This
error
code
appears
after
the
initial
testing
by
the
service
processor
firmware
on
the
CEC
was
completed
correctly,
but
a
problem
occurred
when
the
firmware
tried
to
communicate
outside
the
CEC.
Suspect
a
problem
with
the
RIO
interface,
either
cables
or
adapters.
406A
0200
Self
test
detected
memory
riser
card
fault
Memory
riser
card
1
Location:
U1.1-P1-M1
406A
0201
Self
test
detected
memory
DIMM
fault
Memory
DIMM
1,
riser
1
Location:
U1.1-P1-M1.1
406A
0202
Self
test
detected
memory
DIMM
fault
Memory
DIMM
2,
riser
1
Location:
U1.1-P1-M1.2
406A
0203
Self
test
detected
memory
DIMM
fault
Memory
DIMM
9,
riser
1
Location:
U1.1-P1-M1.9
406A
0204
Self
test
detected
memory
DIMM
fault
Memory
DIMM
10,
riser
1
Location:
U1.1-P1-M1.10
406A
0205
Self
test
detected
memory
DIMM
fault
Memory
DIMM
17,
riser
1
Location:
U1.1-P1-M1.17
406A
0206
Self
test
detected
memory
DIMM
fault
Memory
DIMM
18,
riser
1
Location:
U1.1-P1-M1.18
406A
0207
Self
test
detected
memory
DIMM
fault
Memory
DIMM
25,
riser
1
Location:
U1.1-P1-M1.25
406A
0208
Self
test
detected
memory
DIMM
fault
Memory
DIMM
26,
riser
1
Location:
U1.1-P1-M1.26
406A
020D
Self
test
detected
memory
DIMM
group
fault
Memory
octal
A,
riser
1
Location:
U1.1-P1-M1.1
x8
406A
020E
Self
test
detected
memory
DIMM
group
fault
Memory
quad
A
odd,
riser
1
Locations:
U1.1-P1-M1.1
x4
406A
020F
Self
test
detected
memory
DIMM
group
fault
Memory
quad
A
even,
riser
1
Locations:
U1.1-P1-M1.2
x4
406A
0211
Self
test
detected
memory
DIMM
fault
Memory
DIMM
3,
riser
1
Location:
U1.1-P1-M1.3
406A
0212
Self
test
detected
memory
DIMM
fault
Memory
DIMM
4,
riser
1
Location:
U1.1-P1-M1.4
406A
0213
Self
test
detected
memory
DIMM
fault
Memory
DIMM
11,
riser
1
Location:
U1.1-P1-M1.11
406A
0214
Self
test
detected
memory
DIMM
fault
Memory
DIMM
12,
riser
1
Location:
U1.1-P1-M1.12
406A
0215
Self
test
detected
memory
DIMM
fault
Memory
DIMM
19,
riser
1
Location:
U1.1-P1-M1.19
406A
0216
Self
test
detected
memory
DIMM
fault
Memory
DIMM
20,
riser
1
Location:
U1.1-P1-M1.20
406A
0217
Self
test
detected
memory
DIMM
fault
Memory
DIMM
27,
riser
1
Location:
U1.1-P1-M1.27
406A
0218
Self
test
detected
memory
DIMM
fault
Memory
DIMM
28,
riser
1
Location:
U1.1-P1-M1.28
236
Service
Guide
Summary of Contents for RS/6000 Enterprise Server M80
Page 1: ...RS 6000 Enterprise Server Model M80 Eserver pSeries 660 Model 6M1 Service Guide SA38 0571 01...
Page 10: ...x Service Guide...
Page 14: ...xiv Service Guide...
Page 16: ...xvi Service Guide...
Page 22: ...Data Flow 4 Service Guide...
Page 30: ...CEC Card Cage Rear of CEC drawer viewed from top cover removed 12 Service Guide...
Page 84: ...66 Service Guide...
Page 176: ...158 Service Guide...
Page 376: ...358 Service Guide...
Page 430: ...412 Service Guide...
Page 485: ...Chapter 11 Parts Information This chapter contains parts information for the system 467...
Page 486: ...CEC Drawer Card Assembly 9 468 Service Guide...
Page 488: ...CEC Drawer Backplane 5 2a 1 2 3 4 470 Service Guide...
Page 490: ...CEC Drawer Power Supplies 1 2 3 4 5 6 7 8 9 472 Service Guide...
Page 492: ...CEC Drawer Fan Assemblies 2 1 3 4 5 6 8 9 10 11 12 13 7 14 474 Service Guide...
Page 496: ...7 8 9 10 6 1 2 3 4 4 5 478 Service Guide...
Page 508: ...490 Service Guide...
Page 520: ...502 Service Guide...
Page 522: ...504 Service Guide...
Page 526: ...508 Service Guide...
Page 558: ...540 Service Guide...
Page 565: ......