Table
7.
Service
Processor
Error
Codes
(continued)
Error
Code
Description
Action/
Possible
Failing
FRU
406F
0513
Error
code
generation/logging
detected
memory
DIMM
fault
Memory
DIMM
11,
riser
2
Location:
U1.1-P1-M2.11
406F
0514
Error
code
generation/logging
detected
memory
DIMM
fault
Memory
DIMM
12,
riser
2
Location:
U1.1-P1-M2.12
406F
0515
Error
code
generation/logging
detected
memory
DIMM
fault
Memory
DIMM
19,
riser
2
Location:
U1.1-P1-M2.19
406F
0516
Error
code
generation/logging
detected
memory
DIMM
fault
Memory
DIMM
20,
riser
2
Location:
U1.1-P1-M2.20
406F
0517
Error
code
generation/logging
detected
memory
DIMM
fault
Memory
DIMM
27,
riser
2
Location:
U1.1-P1-M2.27
406F
0518
Error
code
generation/logging
detected
memory
DIMM
fault
Memory
DIMM
28,
riser
2
Location:
U1.1-P1-M2.28
406F
051D
Error
code
generation/logging
detected
memory
DIMM
group
fault
Memory
octal
B,
riser
2
Location:
U1.1-P1-M2.3
x8
406F
051E
Error
code
generation/logging
detected
memory
DIMM
group
fault
Memory
quad
B
odd,
riser
2
Location:
U1.1-P1-M2.3
x4
406F
051F
Error
code
generation/logging
detected
memory
DIMM
group
fault
Memory
quad
B
even,
riser
2
Location:
U1.1-P1-M2.4
x4
406F
0521
Error
code
generation/logging
detected
memory
DIMM
fault
Memory
DIMM
5,
riser
2
Location:
U1.1-P1-M2.5
406F
0522
Error
code
generation/logging
detected
memory
DIMM
fault
Memory
DIMM
6,
riser
2
Location:
U1.1-P1-M2.6
406F
0523
Error
code
generation/logging
detected
memory
DIMM
fault
Memory
DIMM
13,
riser
2
Location:
U1.1-P1-M2.13
406F
0524
Error
code
generation/logging
detected
memory
DIMM
fault
Memory
DIMM
14,
riser
2
Location:
U1.1-P1-M2.14
406F
0525
Error
code
generation/logging
detected
memory
DIMM
fault
Memory
DIMM
21,
riser
2
Location:
U1.1-P1-M2.21
406F
0526
Error
code
generation/logging
detected
memory
DIMM
fault
Memory
DIMM
22,
riser
2
Location:
U1.1-P1-M2.22
406F
0527
Error
code
generation/logging
detected
memory
DIMM
fault
Memory
DIMM
29,
riser
2
Location:
U1.1-P1-M2.29
406F
0528
Error
code
generation/logging
detected
memory
DIMM
fault
Memory
DIMM
30,
riser
2
Location:
U1.1-P1-M2.30
406F
052D
Error
code
generation/logging
detected
memory
DIMM
group
fault
Memory
octal
C,
riser
2
Location:
U1.1-P1-M2.5
x8
406F
052E
Error
code
generation/logging
detected
memory
DIMM
group
pair
A
fault
Memory
quad
C
odd,
riser
2
Location:
U1.1-P1-M2.5
x4
406F
052F
Error
code
generation/logging
detected
memory
DIMM
group
fault
Memory
quad
C
even,
riser
2
Location:
U1.1-P1-M2.6
x4
406F
0531
Error
code
generation/logging
detected
memory
DIMM
fault
Memory
DIMM
7,
riser
2
Location:
U1.1-P1-M2.7
406F
0532
Error
code
generation/logging
detected
memory
DIMM
fault
Memory
DIMM
8,
riser
2
Location:
U1.1-P1-M2.8
406F
0533
Error
code
generation/logging
detected
memory
DIMM
fault
Memory
DIMM
15,
riser
2
Location:
U1.1-P1-M2.15
Chapter
5.
Error
Code
to
FRU
Index
271
Summary of Contents for RS/6000 Enterprise Server M80
Page 1: ...RS 6000 Enterprise Server Model M80 Eserver pSeries 660 Model 6M1 Service Guide SA38 0571 01...
Page 10: ...x Service Guide...
Page 14: ...xiv Service Guide...
Page 16: ...xvi Service Guide...
Page 22: ...Data Flow 4 Service Guide...
Page 30: ...CEC Card Cage Rear of CEC drawer viewed from top cover removed 12 Service Guide...
Page 84: ...66 Service Guide...
Page 176: ...158 Service Guide...
Page 376: ...358 Service Guide...
Page 430: ...412 Service Guide...
Page 485: ...Chapter 11 Parts Information This chapter contains parts information for the system 467...
Page 486: ...CEC Drawer Card Assembly 9 468 Service Guide...
Page 488: ...CEC Drawer Backplane 5 2a 1 2 3 4 470 Service Guide...
Page 490: ...CEC Drawer Power Supplies 1 2 3 4 5 6 7 8 9 472 Service Guide...
Page 492: ...CEC Drawer Fan Assemblies 2 1 3 4 5 6 8 9 10 11 12 13 7 14 474 Service Guide...
Page 496: ...7 8 9 10 6 1 2 3 4 4 5 478 Service Guide...
Page 508: ...490 Service Guide...
Page 520: ...502 Service Guide...
Page 522: ...504 Service Guide...
Page 526: ...508 Service Guide...
Page 558: ...540 Service Guide...
Page 565: ......