Sensor state values during boot process
The key stages of operation.
Initial power on to BMC ready state
In this stage, some indicator values might not reflect the status of the physical sensor. In some
instances, the state is not available because the sensor is not initialized; in this case, the sensor
color is gray. In other cases (typically associated with Host Boot sensors), the value of the sensor
shows the state when the system was operational. These sensors update to indicate the current
status if the display is refreshed when the system reaches the Petitboot stage of operation. Table 3
shows the affected indicators.
BMC ready to PetitBoot or Host operation state
When the system reaches the Petitboot menu stage, and you refresh the display, all of the
indicators reflect their operational state.
Table 3. Sensors and values during the stages of system operation
Sensor Name
Value at BMC Ready
Value at Petitboot or Later
Mem Buf Temp x (x = 0 - 7)
Not Available
Current
CPUx Temp (x = 0 - 1)
Not Available
Current
CPU Core Temp x (x = 0 - 23)
Not Available
Current
DIMMx Temp (x = 0 – 31)
Not Available
Current
GPU Temp x (x = 1 – 4)
Not Available
Current
CPU Diode x (x = 1 – 2)
Current
Current
Ambient Temp
Current
Current
CPU VDD Volt
Not Available
Current
CPU VDD Current
Not Available
Current
Fan x (x = 0 – 5)
Not Available
Current
Mem Buf Func x (X = 0 – 7)
From Previous IPL
Current
DIMM Func x (x = 0 – 31)
From Previous IPL
Current
GPU Func x (x = 1 – 4)
Not Available
Current
CPU Core Func x (x = 0 – 23)
From Previous IPL
Current
CPU Func x (X = 0 – 1)
From Previous IPL
Current
Checkstop
Current
Current
Quick Power Drop
Current
Current
OCC x Active (x = 1 – 2)
Current
Current
PSU Fault x (x = 1 – 2)
Current
Current
All Pgood
Current
Current
FW Boot Progress
From Previous IPL
Current
Host Status
Current
Current
Watchdog
From Previous IPL
Current
System Event
From Previous IPL
Current
OS Boot
From Previous IPL
Current
PCI
From Previous IPL
Current
Mem ProcX Pwr (x = 0 – 3)
Not Available
Current
Procx Power (x = 0 – 1)
Not Available
Current
PCIE Procx Pwr (x = 0 – 1)
Not Available
Current
Common procedures for servicing or installing features
201
Summary of Contents for S822LC
Page 1: ...Power Systems Servicing the IBM Power System S822LC 8335 GTB IBM ...
Page 2: ......
Page 3: ...Power Systems Servicing the IBM Power System S822LC 8335 GTB IBM ...
Page 16: ...xiv Power Systems Servicing the IBM Power System S822LC 8335 GTB ...
Page 204: ...188 Power Systems Servicing the IBM Power System S822LC 8335 GTB ...
Page 242: ...226 Power Systems Servicing the IBM Power System S822LC 8335 GTB ...
Page 243: ......
Page 244: ...IBM ...