Replacing the disk drive and fan card in the 8335-GTB
To replace the disk drive and fan card in the IBM Power System S822LC (8335-GTB) system, complete the
steps in this procedure.
Procedure
1.
Ensure that you have the electrostatic discharge (ESD) wrist strap attached. If not, attach it now.
2.
Remove the replacement disk drive and fan card from the protective plastic envelope.
3.
Using the alignment pins (one on each side) (A) for the disk drive and fan card (B), lower and pivot
the card into place. See Figure 51.
Note:
Both the front USB cable and the power switch cable (A) need to be located in the recessed
area (B) of the disk drive and fan card. If they are not located in that recessed area, they can be
pinched and damaged. See Figure 52 on page 42.
Figure 51. Inserting the disk drive and fan card
Removing and replacing parts in the IBM Power System S822LC (8335-GTB)
41