Service and operating positions for 8335-GCA or 8335-GTA
Learn how to place on an IBM Power System S822LC (8335-GCA and 8335-GTA) system into the service
or operating position.
Placing an 8335-GCA or 8335-GTA system into the service position
Learn how to place an IBM Power System S822LC (8335-GCA and 8335-GTA)system into the service
position.
Before you begin
Notes:
v
When placing the system into the service position, it is essential that all stability plates are firmly
installed to prevent the rack from toppling. Ensure that only one system unit is in the service position
at a time.
v
Ensure that the cables at the rear of the system unit do not catch or bind as you pull the system unit
forward in the rack.
v
When the rails are fully extended, the rail safety latches lock into place. This action prevents the
system from being pulled out too far.
Procedure
1.
Remove the screws on either side of the system that secure the system to the rack.
2.
Push down the front latches (A) that secure the system unit to the rack.
3.
Pull the system unit out of the rack.
Placing an 8335-GCA or 8335-GTA system into the operating position
Learn how to place an IBM Power System S822LC (8335-GCA and 8335-GTA) system into the operating
position.
Figure 112. Placing the system into the srvice position
112
Servicing the IBM Power System S822LC (8335-GCA or 8335-GTA)
Summary of Contents for S822LC
Page 1: ...Power Systems Servicing the IBM Power System S822LC 8335 GCA or 8335 GTA IBM...
Page 2: ......
Page 3: ...Power Systems Servicing the IBM Power System S822LC 8335 GCA or 8335 GTA IBM...
Page 16: ...xiv Servicing the IBM Power System S822LC 8335 GCA or 8335 GTA...
Page 134: ...118 Servicing the IBM Power System S822LC 8335 GCA or 8335 GTA...
Page 145: ...Notices 129...
Page 146: ...IBM Printed in USA...