14.
Are you replacing the TIM or heat sink?
Yes:
Continue with step 15.
No:
Go to step 16 on page 77.
15.
Install a new TIM pad:
a.
If the TIM or heat sink must be replaced, order part number 01AF286, heat sink and TIM.
b.
Open the TIM packaging and carefully remove the TIM, holding it by the edges of the carrier
strip and holding it away from the shipping container.
c.
Remove the protective film from the clear carrier strip by using the supplied tweezers.
Note:
The TIM must remain flat. Small wrinkles are acceptable, but folds are not acceptable.
d.
Using the tweezers, remove the TIM from the carrier strip and center it onto the system
processor module. The side with the red stripe must be facing up. Align the beveled edges of the
TIM and the system processor module (A), as shown in Figure 77 on page 77.
Figure 76. Inspecting the thermal interface material
76