3. Slide the cover towards the back of the enclosure (
3
) back until it stops, as shown in Figure 79 on
Figure 79. Replacing the 2145-92F top cover
4. Verify that the cover correctly engages the cover release latch and all of the inset tabs on the
expansion enclosure.
5. Lock the cover into position by sliding the release lever
4
, as shown in Figure 80 on page 73
Figure 80. Locking the top cover
Installing or replacing a drive: 2145-92F
Use the following procedure to install a drive for the first time or to replace a faulty drive in a 2145-92F
expansion enclosure with a new one received from FRU stock.
Before you begin
Important:
• You can replace a drive assembly without powering off the expansion enclosure. However, to maintain
operating temperature, do not keep the cover off an operational enclosure for more than 15 minutes.
The reduction in airflow through the enclosure might cause the enclosure or its components to shut
down to protect from overheating.
• Ensure that the drive that you are replacing is not a spare or a member of an array. The drive status is
shown in Pools > Internal Storage in the management GUI. If the drive is a member of an array, follow
the fix procedures in the management GUI. The fix procedures minimize the risk of losing data or access
to data; the procedures also manage the system's use of the drive.
Chapter 4. Installing an optional 5U SAS expansion enclosure 73
Summary of Contents for SAN Volume Controller 2145-SV1
Page 1: ...IBM SAN Volume Controller Hardware Installation Guide IBM...
Page 6: ...vi...
Page 48: ...16 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 62: ...30 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 72: ...40 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 168: ...136 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 176: ...144 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 178: ...146 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 182: ...150 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 192: ...160 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 193: ......
Page 194: ...IBM...