Power consumption (maximum configuration)
Model name
@100 VAC input
@200 VAC
input
Minimum number of
power supplies
Notes
SAN128B-6
switch
9.5 A
958.59 VA
942 W
3215.12 BTU/hr
4.55 A
913.13 VA
914 W
3119.56 BTU/hr
1 (Input current and
VA are for 1 PSU.
Watts and BTUs/hr
are with 2 PSUs).
Fully configured all ports with 100%
traffic rate, fans at high speed, and
input power +/- 5% tolerance.
Power consumption (idle configuration)
Model name
@100 VAC
input
@200 VAC input
Minimum number of
power supplies
Notes
SAN128B-6
switch
5.019 A
495 W
1689.47 BTU/hr
2.491 A
484 W
1651.93 BTU/hr
1 (Input current is for
1 PSU. Watts and
BTUs/hr are with 2
PSUs).
No optics loaded and the system
completed boot up, fans at nominal
speed, and input power +/- 5%
tolerance.
Data port specifications (Fibre Channel)
Name
Port
Numbers
Media Type
Description
SAN128B-6
switch
0 to 95
10-, 16-, or 32-Gbps SFP+
optical ports
Can be an F_Port, E_Port, EX_Port, D_Port, or
AE_Port
96 to 127
8 x 16-Gbps (64 Gbps) or 8 x
32-Gbps (128 Gbps) QSFP
optical ports
Can be an F_Port, E_Port, EX_Port, D_Port, or
AE_Port
Fibre Channel data transmission ranges
Port speed
(Gbps)
Cable size
(microns)
Short wavelength (SWL)
Long wavelength
(LWL)
Extended long
wavelength (ELWL)
4
50
150 m (492 ft) (OM2)
380 m (1,264 ft) (OM3)
400 m (1,312 ft) (OM4)
N/A
N/A
62.5
70 m (229 ft)
N/A
N/A
9
N/A
30 km (18.6 miles)
N/A
8
50
50 m (164 ft) (OM2)
150 m (492 ft) (OM3)
190 m (623 ft) (OM4)
N/A
N/A
62.5
21 m (68 ft)
N/A
N/A
9
N/A
10 km (6.2 miles)
N/A
84
SAN128B-6 Installation, Service, and User Guide
Summary of Contents for Storage Networking SAN128B-6
Page 6: ...vi SAN128B 6 Installation Service and User Guide...
Page 8: ...viii SAN128B 6 Installation Service and User Guide...
Page 84: ...64 SAN128B 6 Installation Service and User Guide...
Page 100: ...80 SAN128B 6 Installation Service and User Guide...
Page 114: ...94 SAN128B 6 Installation Service and User Guide...
Page 115: ......
Page 116: ...IBM Part Number 01JC270 Printed in USA SC27 9251 00 1P P N 01JC270...