Table 29. Temperature requirements (continued)
Environment
Ambient
temperature
Altitude
Relative humidity
Maximum wet bulb
temperature
Non-operating
1°C to 50°C
(34°F to 122°F)
-305 to 12192 m
(-1000 to 40000 ft)
8% to 80%
noncondensing
27°C (80°F)
Storage
1°C to 60°C
(34°F to 140°F)
5% to 80%
noncondensing
29°C (84°F)
Shipping
-40°C to 60°C
(-40°F to 140°F)
5% to 100%
condensing, but not
precipitating
Dimensions and weight requirements for rack installation
Ensure that space is available in a standard 19" rack that is capable of supporting the enclosure. The rack
rail kits support racks with either threaded round or square rail mounting holes. The following table lists
the dimensions and weights of the expansion enclosures.
Table 30. Physical characteristics of the expansion enclosures
Enclosure
Height
Width
Depth
Maximum weight
Drive ready
(without
drive
modules)
Fully
configured
(with drive
modules)
2077/2078-12F or
2077/2078-24F or
2077/2078-AFF
87 mm (3.46
in.)
483 mm
(19.0 in.)
556 mm (21.9
in.)
16.7 kg (36.8
lb)
25.0 kg (55.1
lb)
Appendix D. SAS expansion enclosure requirements 105
Summary of Contents for Storwize V5100 MTM 2078-424
Page 143: ......