Table 26. Error event IDs and error codes (continued)
Event
ID
Notification
type
Condition
Error
code
010097
E
A drive is reporting excessive errors.
1685
010098
W
There are too many drives presented to a cluster
(system).
1200
020001
E
There are too many medium errors on the managed disk. 1610
020002
E
A managed disk group is offline.
1620
020003
W
There are insufficient virtual extents.
2030
029001
W
The managed disk has bad blocks.
1840
029002
E
The system failed to create a bad block because MDisk
already has the maximum number of allowed bad
blocks.
1226
029003
E
The system failed to create a bad block because the
clustered system already has the maximum number of
allowed bad blocks.
1225
030000
W
The
trigger prepare
command has failed because of a
cache flush failure.
1900
030010
W
The mapping is stopped because of the error that is
indicated in the data.
1910
030020
W
The mapping is stopped because of a clustered system or
complete I/O group failure, and the current state of the
relationship could not be recovered.
1895
045001
E
One or more power supply unit fans have failed.
1124
045002
E
A fan is operating outside the expected range.
1126
045003
E
There was a fan status communications failure.
1126
045004
E
The power supply unit is not installed.
1128
045005
W
The power supply unit has indicated an input power
failure.
1138
045006
E
The power supply unit has indicated a dc failure.
1126
045007
E
The power supply unit has failed.
1124
045008
E
There is no communication with the power supply unit.
1148
045009
E
The model type for this enclosure is not valid.
1124
045010
E
The power supply unit type is unknown to this product.
1124
045011
E
The power supply unit serial number is not valid.
1124
045012
W
The canister temperature is at the warning level.
1098
045013
W
The canister temperature is at the critical level.
1095
045014
E
The SAS cable was excluded because of a missing device. 1260
045015
E
A SAS cable was excluded because too many change
events were caused.
1260
045016
E
A SAS cable was excluded.
1255
045017
E
A SAS cable is operating at a reduced speed.
1260
045018
E
A SAS cable was excluded because frames were dropped. 1260
045019
E
A SAS cable was excluded because the enclosure
discovery timed out.
1260
045020
W
A SAS cable is not present.
1265
124
Storwize V7000: Troubleshooting, Recovery, and Maintenance Guide
Summary of Contents for Storwize V7000
Page 1: ...IBM Storwize V7000 Version 6 3 0 Troubleshooting Recovery and Maintenance Guide GC27 2291 02...
Page 6: ...vi Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Page 8: ...viii Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Page 10: ...x Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Page 34: ...18 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Page 42: ...26 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Page 80: ...64 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Page 128: ...112 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Page 156: ...140 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Page 166: ...150 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Page 171: ......
Page 172: ...Printed in USA GC27 2291 02...