and data (if needed). All 10 Gbps Ethernet ports are dedicated to data.
Management cannot be performed over the 10 Gbps Ethernet.
Note:
It is important that the file modules are able to communicate over the
network with the Storwize V7000 control enclosure for management, service and
optional file access.
v
1
Fibre Channel ports (8 Gbps). Each canister has four Fibre Channel ports.
They are in a block of four in two rows of two connectors. The ports are
numbered 1 - 4 from left to right, top to bottom. Two ports connect to the file
modules and two are connected to the SAN.
v
2
USB ports. Each canister has two USB ports. The ports are side by side on
the canister and are numbered 1 on the left and 2 on the right. One port is used
during installation.
v
3
Ethernet ports (1 Gbps). Each canister has two Ethernet ports. The ports are
side by side on the canister. They are numbered 1 on the left and 2 on the right
on the upper canister. The port locations are inverted for the lower canister. Port
1 must be connected first; the use of port 2 is optional.
v
4
Serial-attached SCSI (SAS) ports (6 Gbps). Each canister has two SAS ports.
The ports are side by side on the canister. They are numbered 1 on the left and 2
on the right. Port 1 must be connected first if you are adding one expansion
enclosure. Port 2 must be connected if you are adding a second expansion
enclosure.
CAUTIO N
CAU
TIO
N
CAUT
IO
N
CAUT I O N
Disconnect all
supply power for
complete isolation
Disconnect all
supply power for
complete isolation
Disconnect all
supply power for
complete isolation
Disconnect all
supply power for
complete isolation
1
2
3
4
1
2
3
4
ifs00044
Figure 50. Control enclosure Ethernet network connections.
fab10001
Figure 51. Storwize V7000 Gen2 control enclosure Ethernet network connections
90
IBM Storwize V7000 Unified: Adding Storwize V7000 File Modules to an existing Storwize V7000 system 2073-720