Table 49. LED status rear of expansion enclosure.
Hardware component
LED name and symbol
If power on and no fault is
detected
Expansion canister, rear. The
reference to the top and
bottom locations applies to
canister 1, which is the upper
canister. The LED locations
are inverted for canister 2,
which is the lower canister.
Canister status, top
LED is on.
Fault status, bottom
LED is off.
SAS ports
When a SAS port is
functioning correctly, all four
green LEDs above the port
are on. If no cable is plugged
into the port, or if the
canister at either end of the
cable is not yet fully started,
the LEDs are not on.
Power supply unit,
expansion enclosure. The
reference to the left and right
locations applies to power
supply unit 1, which is the
left power supply. The LED
locations are inverted for
power supply unit 2, which
is the right power supply.
Power supply, upper right
LED is on.
Fan failure
LED is off.
dc power failure
LED is off.
ac power failure
LED is off.
Powering on a control enclosure:
1
svc00671
1
Figure 61. LEDs on the power supply units of the expansion enclosure