Figure 11 shows the rear view of a model 2076-112 or a model 2076-124 control
enclosure and identifies the location of the ports.
v
1
Fibre Channel ports. Each canister has four Fibre Channel ports. They are in
a block of four in two rows of two connectors. The ports are numbered 1 - 4
from left to right, top to bottom. Two ports connect to the file modules and two
are optional.
v
2
USB ports. Each canister has two USB ports. The ports are side by side on
the canister and are numbered 1 on the left and 2 on the right. One port is used
during installation.
v
3
Ethernet ports. Each canister has two Ethernet ports. The ports are side by
side on the canister. They are numbered 1 on the left and 2 on the right on the
upper canister. The port locations are inverted for the lower canister. Port 1 must
be connected first; the use of port 2 is optional.
v
4
Serial-attached SCSI (SAS) ports. Each canister has two SAS ports. The ports
are side by side on the canister. They are numbered 1 on the left and 2 on the
right. Port 1 must be connected first if you are adding one expansion enclosure.
Port 2 must be connected if you are adding a second expansion enclosure.
Note:
The reference to the left and right locations applies to canister 1, which is
the upper canister. The port locations are inverted for canister 2, which is the lower
canister.
Figure 12 on page 46 shows the rear view of a model 2076-312 or a model 2076-324
control enclosure with the optional 10 Gbps Ethernet ports installed. All other
ports remain the same.
svc00669
1
4
2
3
1
4
2
3
Figure 11. This figure shows the data ports in the rear of the control enclosure.
Chapter 3. Before you begin adding file modules
45