Installing the 3U chassis hard disk drive backplane
To install the 3U chassis hard disk drive backplane, complete the following steps.
1. Touch the static-protective package that contains the hard disk drive backplane
to any
unpainted
metal surface on the outside of the 3U chassis; then, remove
the hard disk drive backplane from the package.
2. Position the hard disk drive backplane in the 3U chassis and secure it with ten
screws.
3. Install the power-supply paddle card and power supply (see “Installing the 3U
chassis power supply and power-supply paddle card” on page 133).
4. Install the system-board tray in the 3U chassis (see “Installing the system-board
tray in a 3U chassis” on page 78).
5. Install the fan assembly (see “Installing the 3U chassis fan assembly” on page
6. Install the top cover (see“Installing the 3U chassis top cover” on page 85 ).
7. Install the 3U chassis in the iDataPlex rack (see “Installing a 3U chassis in a
Type 7825 iDataPlex rack” on page 130).
8. Install the hard disk drives (see “Removing and installing a hard disk drive” on
128
System x iDataPlex dx340 Types 6385, 6386, 6389, 7831, 7832, and 7834: Problem Determination and Service Guide