806f0413-2582ffff
A PCI PERR has occurred on
system
[ComputerSystemElementName].
(PCIs)
Explanation:
This message is for the use case when
an implementation has detected a PCI PERR.
Internal Event:
No
Severity:
Error
Alert Category:
Critical - Other
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0232
SNMP Trap ID:
50
Automatically notify Support:
No
User response:
1.
Check the PCI LED.
2.
Reseat the affected adapters and riser cards.
3.
Update the server firmware (UEFI and IMM) and
adapter firmware. Important: Some cluster solutions
require specific code levels or coordinated code
updates. If the device is part of a cluster solution,
verify that the latest level of code is supported for
the cluster solution before you update the code.
4.
Remove both adapters.
5.
Replace the PCIe adapters.
6.
Replace the riser card.
806f0507-0301ffff
[ProcessorElementName] has a
Configuration Mismatch. (CPU 1)
Explanation:
This message is for the use case when
an implementation has detected a Processor
Configuration Mismatch has occurred.
Internal Event:
No
Severity:
Error
Alert Category:
Critical - CPU
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0062
SNMP Trap ID:
40
Automatically notify Support:
No
User response:
1.
Make sure that the installed microprocessors are
compatible with each other.
2.
(Trained technician only) Reseat microprocessor n.
3.
(Trained technician only) Replace microprocessor
n. (n = microprocessor number)
806f0507-0302ffff
[ProcessorElementName] has a
Configuration Mismatch. (CPU 2)
Explanation:
This message is for the use case when
an implementation has detected a Processor
Configuration Mismatch has occurred.
Internal Event:
No
Severity:
Error
Alert Category:
Critical - CPU
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0062
SNMP Trap ID:
40
Automatically notify Support:
No
User response:
1.
Make sure that the installed microprocessors are
compatible with each other.
2.
(Trained technician only) Reseat microprocessor n.
3.
(Trained technician only) Replace microprocessor
n. (n = microprocessor number)
806f0507-2584ffff
[ProcessorElementName] has a
Configuration Mismatch. (All CPUs)
Explanation:
This message is for the use case when
an implementation has detected a Processor
Configuration Mismatch has occurred.
Internal Event:
No
Severity:
Error
Alert Category:
Critical - CPU
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0062
SNMP Trap ID:
40
Automatically notify Support:
No
User response:
1.
Make sure that the installed microprocessors are
compatible with each other.
2.
(Trained technician only) Reseat microprocessor n.
3.
(Trained technician only) Replace microprocessor
n. (n = microprocessor number)
One of the CPUs :
806f050c-2001ffff
Memory Logging Limit Reached
for [PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
(DIMM 1)
Explanation:
This message is for the use case when
an implementation has detected that the Memory
Logging Limit has been Reached.
806f0413-2582ffff • 806f050c-2001ffff
Chapter 3. Diagnostics
101
Summary of Contents for System x iDataPlex dx360 M4 7912
Page 1: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 22: ...4 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 278: ...260 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 292: ...274 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 392: ...374 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 399: ......
Page 400: ...Part Number 46W8218 Printed in USA 1P P N 46W8218...