806f072b-2201ffff
A successful software or
firmware change was detected on
system
[ComputerSystemElementName]. (Bkup
Auto Update)
Explanation:
This message is for the use case when
an implementation has detected a Successful Software
or Firmware Change.
Internal Event:
No
Severity:
Info
Alert Category:
System - Other
Serviceable:
No
CIM Information: Prefix:
PLAT and
ID:
0450
SNMP Trap ID:
Automatically notify Support:
No
User response:
No action; information only. ROM
Recovery :
806f0807-0301ffff
[ProcessorElementName] has
been Disabled. (CPU 1)
Explanation:
This message is for the use case when
an implementation has detected a Processor has been
Disabled.
Internal Event:
No
Severity:
Info
Alert Category:
System - Other
Serviceable:
No
CIM Information: Prefix:
PLAT and
ID:
0061
SNMP Trap ID:
Automatically notify Support:
No
User response:
No action; information only.
806f0807-0302ffff
[ProcessorElementName] has
been Disabled. (CPU 2)
Explanation:
This message is for the use case when
an implementation has detected a Processor has been
Disabled.
Internal Event:
No
Severity:
Info
Alert Category:
System - Other
Serviceable:
No
CIM Information: Prefix:
PLAT and
ID:
0061
SNMP Trap ID:
Automatically notify Support:
No
User response:
No action; information only.
806f0807-2584ffff
[ProcessorElementName] has
been Disabled. (All CPUs)
Explanation:
This message is for the use case when
an implementation has detected a Processor has been
Disabled.
Internal Event:
No
Severity:
Info
Alert Category:
System - Other
Serviceable:
No
CIM Information: Prefix:
PLAT and
ID:
0061
SNMP Trap ID:
Automatically notify Support:
No
User response:
No action; information only. One of
the CPUs :
806f0813-2581ffff
A Uncorrectable Bus Error has
occurred on system
[ComputerSystemElementName].
(DIMMs)
Explanation:
This message is for the use case when
an implementation has detected a Bus Uncorrectable
Error.
Internal Event:
No
Severity:
Error
Alert Category:
Critical - Other
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0240
SNMP Trap ID:
50
Automatically notify Support:
Yes
User response:
1.
Check the system-event log.
2.
Check the DIMM error LEDs.
3.
Remove the failing DIMM from the system board.
4.
Check for a server firmware update. Important:
Some cluster solutions require specific code levels
or coordinated code updates. If the device is part of
a cluster solution, verify that the latest level of code
is supported for the cluster solution before you
update the code.
5.
Make sure that the installed DIMMs are supported
and configured correctly.
6.
(Trained technician only) Replace the system
board.
806f072b-2201ffff • 806f0813-2581ffff
114
System x iDataPlex dx360 M4 Types 7912 and 7913: Problem Determination and Service Guide
Summary of Contents for System x iDataPlex dx360 M4 7912
Page 1: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 22: ...4 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 278: ...260 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 292: ...274 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 392: ...374 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 399: ......
Page 400: ...Part Number 46W8218 Printed in USA 1P P N 46W8218...