806f0813-2582ffff
A Uncorrectable Bus Error has
occurred on system
[ComputerSystemElementName].
(PCIs)
Explanation:
This message is for the use case when
an implementation has detected a Bus Uncorrectable
Error.
Internal Event:
No
Severity:
Error
Alert Category:
Critical - Other
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0240
SNMP Trap ID:
50
Automatically notify Support:
Yes
User response:
1.
Check the system-event log.
2.
Check the PCI LED.
3.
Remove the adapter from the indicated PCI slot.
4.
Check for a server firmware update. Important:
Some cluster solutions require specific code levels
or coordinated code updates. If the device is part of
a cluster solution, verify that the latest level of code
is supported for the cluster solution before you
update the code.
5.
(Trained technician only) Replace the system
board.
806f0813-2584ffff
A Uncorrectable Bus Error has
occurred on system
[ComputerSystemElementName].
(CPUs)
Explanation:
This message is for the use case when
an implementation has detected a Bus Uncorrectable
Error.
Internal Event:
No
Severity:
Error
Alert Category:
Critical - Other
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0240
SNMP Trap ID:
50
Automatically notify Support:
Yes
User response:
1.
Check the system-event log.
2.
(Trained technician only) Remove the failing
microprocessor from the system board (see
Removing a microprocessor and heat sink).
3.
Check for a server firmware update. Important:
Some cluster solutions require specific code levels
or coordinated code updates. If the device is part of
a cluster solution, verify that the latest level of code
is supported for the cluster solution before you
update the code.
4.
Make sure that the two microprocessors are
matching.
5.
(Trained technician only) Replace the system
board.
806f0823-2101ffff
Watchdog Timer interrupt
occurred for [WatchdogElementName].
(IPMI Watchdog)
Explanation:
This message is for the use case when
an implementation has detected a Watchdog Timer
interrupt occurred.
Internal Event:
No
Severity:
Info
Alert Category:
System - Other
Serviceable:
No
CIM Information: Prefix:
PLAT and
ID:
0376
SNMP Trap ID:
Automatically notify Support:
No
User response:
No action; information only.
806f090c-2001ffff
[PhysicalMemoryElementName]
on Subsystem [MemoryElementName]
Throttled. (DIMM 1)
Explanation:
This message is for the use case when
an implementation has detected Memory has been
Throttled.
Internal Event:
No
Severity:
Warning
Alert Category:
System - Other
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0142
SNMP Trap ID:
22
Automatically notify Support:
No
User response:
1.
Reseat the DIMM, and then restart the server.
2.
Replace DIMM n. (n = DIMM number)
806f090c-2002ffff
[PhysicalMemoryElementName]
on Subsystem [MemoryElementName]
Throttled. (DIMM 2)
Explanation:
This message is for the use case when
an implementation has detected Memory has been
Throttled.
806f0813-2582ffff • 806f090c-2002ffff
Chapter 3. Diagnostics
115
Summary of Contents for System x iDataPlex dx360 M4 7912
Page 1: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 22: ...4 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 278: ...260 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 292: ...274 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 392: ...374 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 399: ......
Page 400: ...Part Number 46W8218 Printed in USA 1P P N 46W8218...