816f010c-2581ffff
Uncorrectable error recovery
detected for
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName]. (All
DIMMS)
Explanation:
This message is for the use case when
an implementation has detected a Memory
uncorrectable error recovery.
Internal Event:
No
Severity:
Info
Alert Category:
Critical - Memory
Serviceable:
No
CIM Information: Prefix:
PLAT and
ID:
0139
SNMP Trap ID:
41
Automatically notify Support:
No
User response:
No action; information only. One of
the DIMMs :
816f010f-2201ffff
The System
[ComputerSystemElementName] has
recovered from a firmware hang.
(Firmware Error)
Explanation:
This message is for the use case when
an implementation has recovered from a System
Firmware Hang.
Internal Event:
No
Severity:
Info
Alert Category:
Critical - Other
Serviceable:
No
CIM Information: Prefix:
PLAT and
ID:
0187
SNMP Trap ID:
50
Automatically notify Support:
No
User response:
No action; information only.
816f0113-0301ffff
System
[ComputerSystemElementName] has
recovered from a bus timeout. (CPU 1
PECI)
Explanation:
This message is for the use case when
an implemenation has detected that a system has
recovered from a Bus Timeout.
Internal Event:
No
Severity:
Info
Alert Category:
Critical - Other
Serviceable:
No
CIM Information: Prefix:
PLAT and
ID:
0225
SNMP Trap ID:
50
Automatically notify Support:
No
User response:
1.
(Trained technician only) Replace microprocessor n
(see Removing a microprocessor and heat sink and
Replacing a microprocessor and heat sink).
2.
If the problem persists and there is no other CPU
with the same error indication, replace the system
board.
3.
(Trained technician only) Replace the system board
(see Removing the system board and Replacing the
system board). (n = microprocessor number)
816f0113-0302ffff
System
[ComputerSystemElementName] has
recovered from a bus timeout. (CPU 2
PECI)
Explanation:
This message is for the use case when
an implemenation has detected that a system has
recovered from a Bus Timeout.
Internal Event:
No
Severity:
Info
Alert Category:
Critical - Other
Serviceable:
No
CIM Information: Prefix:
PLAT and
ID:
0225
SNMP Trap ID:
50
Automatically notify Support:
No
User response:
1.
(Trained technician only) Replace microprocessor n
(see Removing a microprocessor and heat sink and
Replacing a microprocessor and heat sink).
2.
If the problem persists and there is no other CPU
with the same error indication, replace the system
board.
3.
(Trained technician only) Replace the system board
(see Removing the system board and Replacing the
system board). (n = microprocessor number)
816f0125-0b01ffff
[ManagedElementName]
detected as present. (PCI Riser 1)
Explanation:
This message is for the use case when
an implementation has detected a Managed Element is
now Present.
Internal Event:
No
Severity:
Info
Alert Category:
System - Other
Serviceable:
No
CIM Information: Prefix:
PLAT and
ID:
0390
SNMP Trap ID:
816f010c-2581ffff • 816f0125-0b01ffff
142
System x iDataPlex dx360 M4 Types 7912 and 7913: Problem Determination and Service Guide
Summary of Contents for System x iDataPlex dx360 M4 7912
Page 1: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 22: ...4 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 278: ...260 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 292: ...274 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 392: ...374 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 399: ......