816f0a0c-200effff
An Over-Temperature Condition
has been removed on the
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
(DIMM 14)
Explanation:
This message is for the use case when
an implementation has detected an Over Temperature
Condition for Memory that has been Removed.
Internal Event:
No
Severity:
Info
Alert Category:
Critical - Temperature
Serviceable:
No
CIM Information: Prefix:
PLAT and
ID:
0147
SNMP Trap ID:
0
Automatically notify Support:
No
User response:
No action; information only.
816f0a0c-200fffff
An Over-Temperature Condition
has been removed on the
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
(DIMM 15)
Explanation:
This message is for the use case when
an implementation has detected an Over Temperature
Condition for Memory that has been Removed.
Internal Event:
No
Severity:
Info
Alert Category:
Critical - Temperature
Serviceable:
No
CIM Information: Prefix:
PLAT and
ID:
0147
SNMP Trap ID:
0
Automatically notify Support:
No
User response:
No action; information only.
816f0a0c-2010ffff
An Over-Temperature Condition
has been removed on the
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
(DIMM 16)
Explanation:
This message is for the use case when
an implementation has detected an Over Temperature
Condition for Memory that has been Removed.
Internal Event:
No
Severity:
Info
Alert Category:
Critical - Temperature
Serviceable:
No
CIM Information: Prefix:
PLAT and
ID:
0147
SNMP Trap ID:
0
Automatically notify Support:
No
User response:
No action; information only.
816f0a13-0301ffff
System
[ComputerSystemElementName] has
recovered from a Fatal Bus Error. (CPU
1 PECI)
Explanation:
This message is for the use case when
an implementation has detected that a system has
recovered from a Bus Fatal Error.
Internal Event:
No
Severity:
Info
Alert Category:
Critical - Other
Serviceable:
No
CIM Information: Prefix:
PLAT and
ID:
0245
SNMP Trap ID:
50
Automatically notify Support:
No
User response:
1.
(Trained technician only) Replace microprocessor n
(see Removing a microprocessor and heat sink and
Replacing a microprocessor and heat sink).
2.
If the problem persists and there is no other CPU
with the same error indication, replace the system
board.
3.
(Trained technician only) Replace the system board
(see Removing the system board and Replacing the
system board). (n = microprocessor number)
816f0a13-0302ffff
System
[ComputerSystemElementName] has
recovered from a Fatal Bus Error. (CPU
2 PECI)
Explanation:
This message is for the use case when
an implementation has detected that a system has
recovered from a Bus Fatal Error.
Internal Event:
No
Severity:
Info
Alert Category:
Critical - Other
Serviceable:
No
CIM Information: Prefix:
PLAT and
ID:
0245
SNMP Trap ID:
50
Automatically notify Support:
No
User response:
816f0a0c-200effff • 816f0a13-0302ffff
164
System x iDataPlex dx360 M4 Types 7912 and 7913: Problem Determination and Service Guide
Summary of Contents for System x iDataPlex dx360 M4 7912
Page 1: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 22: ...4 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 278: ...260 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 292: ...274 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 392: ...374 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 399: ......
Page 400: ...Part Number 46W8218 Printed in USA 1P P N 46W8218...