218-903-000 Brocade:PCILoopbackTest Failed
Explanation:
A failure was detected during the
Loopback test.
Internal Event:
No
Severity:
Error
Serviceable:
Yes
Recoverable:
No
Automatically notify Support:
No
User response:
Complete the following steps:
1. Rerun the test.
2. Verify whether the firmware is at proper level.
3. Rerun the test.
4. If the problem remains, contact your IBM
technical-support representative.
Date Message Added:
09/03/2012
Reviewed:
09/03/2012
218-904-000 Brocade:ExternalEthLoopbackTest
Failed
Explanation:
A failure was detected during the
Loopback test.
Internal Event:
No
Severity:
Error
Serviceable:
Yes
Recoverable:
No
Automatically notify Support:
No
User response:
Complete the following steps:
1. Check or replace SFP/cable.
2. Rerun the test.
3. Verify whether the firmware is at proper level.
4. Rerun the test.
5. If the problem remains, contact your IBM
technical-support representative.
Date Message Added:
09/03/2012
Reviewed:
09/03/2012
218-905-000 Brocade:SerdesEthLoopbackTest
Failed
Explanation:
A failure was detected during the
Loopback test.
Internal Event:
No
Severity:
Error
Serviceable:
Yes
Recoverable:
No
Automatically notify Support:
No
User response:
Complete the following steps:
1. Rerun the test.
2. Verify whether the firmware is at proper level.
3. Rerun the test.
4. If the problem remains, contact your IBM
technical-support representative.
Date Message Added:
09/03/2012
Reviewed:
09/03/2012
218-906-000 Brocade:InternalLoopbackTest Failed
Explanation:
A failure was detected during the
Loopback test.
Internal Event:
No
Severity:
Error
Serviceable:
Yes
Recoverable:
No
Automatically notify Support:
No
User response:
Complete the following steps:
1. Rerun the test.
2. Verify whether the firmware is at proper level.
3. Rerun the test.
4. If the problem remains, contact your IBM
technical-support representative.
Date Message Added:
09/03/2012
Reviewed:
09/03/2012
180-000-000 Check-point Panel Test Passed
Explanation:
Check-point Panel Test Passed.
Internal Event:
No
Severity:
Event
Serviceable:
No
Recoverable:
No
Automatically notify Support:
No
Date Message Added:
08/29/2012
Reviewed:
08/29/2012
180-801-000 Check-point Panel Test Aborted
Explanation:
Check-point Panel Test Aborted. BMC is
unable to verify that the operator information panel
cable is connected.
Internal Event:
No
Severity:
Warning
Serviceable:
Yes
218-903-000 • 180-801-000
198
System x iDataPlex dx360 M4 Types 7912 and 7913: Problem Determination and Service Guide
Summary of Contents for System x iDataPlex dx360 M4 7912
Page 1: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 22: ...4 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 278: ...260 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 292: ...274 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 392: ...374 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 399: ......
Page 400: ...Part Number 46W8218 Printed in USA 1P P N 46W8218...