5. Run the test again.
6. If the system has stopped responding, turn off and
restart the system and then run the test again.
7. If failure remains, refer to "Troubleshooting by
symptom" in the system "Installation and Service
Guide" for the next corrective action.
Date Message Added:
07/30/2012
Reviewed:
08/29/2012
089-803-000 CPU Stress Test Aborted
Explanation:
CPU Stress Test Aborted. Memory size
is insufficient to run the test. At least 1GB is required.
Internal Event:
No
Severity:
Warning
Serviceable:
Yes
Recoverable:
No
Automatically notify Support:
No
Date Message Added:
07/30/2012
Reviewed:
08/13/2012
089-804-000 CPU Stress Test Aborted
Explanation:
CPU Stress Test Aborted. User pressed
Ctrl-C.
Internal Event:
No
Severity:
Warning
Serviceable:
Yes
Recoverable:
No
Automatically notify Support:
No
Date Message Added:
07/30/2012
Reviewed:
08/13/2012
089-901-000 CPU Stress Test Failed
Explanation:
CPU Stress Test Failed.
Internal Event:
No
Severity:
Error
Serviceable:
Yes
Recoverable:
No
Automatically notify Support:
No
User response:
Complete the following steps:
1. If the system has stopped responding, turn off and
restart the system and then run the test again.
2. Make sure that the DSA Diagnostic code is at the
latest level.
3. Run the test again.
4. Check system firmware level and upgrade if
necessary. The installed firmware level can be found
in the DSA Diagnostic Event Log within the
Firmware/VPD section for this component.
5. Run the test again.
6. If the system has stopped responding, turn off and
restart the system and then run the test again.
7. If failure remains, refer to "Troubleshooting by
symptom" in the system "Installation and Service
Guide" for the next corrective action.
Date Message Added:
07/30/2012
Reviewed:
08/29/2012
516-000-000 ELXUCNA: NIC MAC LoopBackTest
Passed
Explanation:
The test passed.
Internal Event:
No
Severity:
Event
Serviceable:
No
Recoverable:
No
Automatically notify Support:
No
Date Message Added:
09/03/2012
Reviewed:
09/03/2012
516-001-000 ELXUCNA: NIC PHY LoopBackTest
Passed
Explanation:
The test passed.
Internal Event:
No
Severity:
Event
Serviceable:
No
Recoverable:
No
Automatically notify Support:
No
Date Message Added:
09/03/2012
Reviewed:
09/03/2012
516-002-000 ELXUCNA: ELXUCNA: NIC
LED(Beacon)Test Passed
Explanation:
The test passed.
Internal Event:
No
Severity:
Event
Serviceable:
No
Recoverable:
No
Automatically notify Support:
No
Date Message Added:
09/03/2012
089-803-000 • 516-002-000
200
System x iDataPlex dx360 M4 Types 7912 and 7913: Problem Determination and Service Guide
Summary of Contents for System x iDataPlex dx360 M4 7912
Page 1: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 22: ...4 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 278: ...260 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 292: ...274 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 392: ...374 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 399: ......
Page 400: ...Part Number 46W8218 Printed in USA 1P P N 46W8218...