Automatically notify Support:
No
User response:
Perform the actions mentioned one at
a time and try the test after each action:
1. Turn off the system and disconnect it from power.
Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest
level.
Date Message Added:
11/12/2013
Reviewed:
11/12/2013
166-824-001 IMM I2C Test Aborted
Explanation:
Cannot execute command.
Internal Event:
No
Severity:
Warning
Serviceable:
Yes
Recoverable:
No
Automatically notify Support:
No
User response:
Perform the actions mentioned one at
a time and try the test after each action:
1. Turn off the system and disconnect it from power.
Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest
level.
Date Message Added:
11/12/2013
Reviewed:
11/12/2013
166-901-001 IMM I2C Test Failed
Explanation:
IMM Indicates failure in Private bus
(BUS 0).
Internal Event:
No
Severity:
Error
Serviceable:
Yes
Recoverable:
No
Automatically notify Support:
No
User response:
Perform the actions mentioned one at
a time and try the test after each action:
1. Turn off the system and disconnect it from power.
Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest
level.
3. Run the test again.
4. If failure remains, refer to "Troubleshooting by
symptom" in the system "Installation and Service
Guide" for the next corrective action.
Date Message Added:
11/12/2013
Reviewed:
11/12/2013
166-904-001 IMM I2C Test Failed
Explanation:
IMM Indicates failure in LED bus (BUS
3).
Internal Event:
No
Severity:
Error
Serviceable:
Yes
Recoverable:
No
Automatically notify Support:
No
User response:
Perform the actions mentioned one at
a time and try the test after each action:
1. Turn off the system and disconnect it from power.
Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest
level.
3. Run the test again.
4. If failure remains, refer to "Troubleshooting by
symptom" in the system "Installation and Service
Guide" for the next corrective action.
Date Message Added:
11/12/2013
Reviewed:
11/12/2013
166-905-001 IMM I2C Test Failed
Explanation:
IMM Indicates failure in Power Supply
bus (BUS 4).
Internal Event:
No
Severity:
Error
Serviceable:
Yes
Recoverable:
No
Automatically notify Support:
No
User response:
Perform the actions mentioned one at
a time and try the test after each action:
1. Turn off the system and disconnect it from power.
Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest
level.
3. Run the test again.
4. If failure remains, refer to "Troubleshooting by
symptom" in the system "Installation and Service
Guide" for the next corrective action.
Date Message Added:
11/12/2013
Reviewed:
11/12/2013
166-906-001 IMM I2C Test Failed
Explanation:
IMM Indicates failure in in PCH bus
(BUS 5).
Internal Event:
No
166-824-001 • 166-906-001
Chapter 3. Diagnostics
249
Summary of Contents for System x iDataPlex dx360 M4 7912
Page 1: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 22: ...4 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 278: ...260 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 292: ...274 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 392: ...374 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 399: ......
Page 400: ...Part Number 46W8218 Printed in USA 1P P N 46W8218...