2U chassis
Release latch
Power supply
1. Read the safety information that begins on page vii and “Installation guidelines”
2. If the chassis that contains the power supply is installed in an iDataPlex with the
rail having the power cord retention feature, remove it off from the rack (see
“Removing the 2U chassis from a rack” on page 284).
3. Remove the power cord if there is any attached to the power supply (see
“Removing the power cord from the rail without power cord mounting bracket”
on page 298).
4. Carefully pull the power supply out of the chassis.
5. If you are instructed to return the power supply, follow all packaging instructions,
and use any packaging materials for shipping that are supplied to you.
Installing a power supply in a 2U chassis
Notes:
1. If you are installing a 900 watt redundant power supply unit, make sure the
input power is phase-to-phase, or, phase-to-neutral, 200 volt to 240 volt
nominal, AC, 47-63 Hz.
2. Both plugs of 900 watt redundant power supply should be plugged in to PDU or
outlet together.
Table 14 shows the power supply configuration.
Table 14. Power supply configuration
Microprocessor
SKU
750 W fixed
module
900 W fixed
module
750 W
redundant
module
900 W
redundant
module
130 W with more
than 8 DIMMs
Not available
x2
Not available
Not available
130 W with less
than or equal to
8 DIMMs
Not available
x1
Not available
x2
Chapter 5. Removing and replacing server components
317
Summary of Contents for System x iDataPlex dx360 M4 7912
Page 1: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 22: ...4 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 278: ...260 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 292: ...274 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 392: ...374 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 399: ......
Page 400: ...Part Number 46W8218 Printed in USA 1P P N 46W8218...