microprocessor, and then lift the microprocessor out of the socket.
Installation tool
Microprocessor
Handle
d. Lift the microprocessor out of the socket.
Installation tool
Microprocessor
8. If you do not intend to install a microprocessor on the socket, install the socket
cover that you removed in step 6 on page 333 on the microprocessor socket.
Attention:
The pins on the socket are fragile. Any damage to the pins may
require replacing the system board.
9. If you are instructed to return the microprocessor, follow all packaging
instructions, and use any packaging materials for shipping that are supplied to
you.
Installing a microprocessor and heat sink
The following notes describe the type of microprocessor that the server supports
and other information that you must consider when you install a microprocessor and
heat sink:
v
Microprocessors are to be installed only by trained technicians.
Important:
Always use the microprocessor installation tool to install a
microprocessor. Failing to use the microprocessor installation tool may damage
the microprocessor sockets on the system board. Any damage to the
microprocessor sockets may require replacing the system board.
v
Be extremely careful, the microprocessor socket contacts are very fragile. Do not
touch the microprocessor socket contacts. Contaminants on the microprocessor
contacts or microprocessor socket contacts, such as oil from your skin, can
cause connection failures between the contacts and the socket.
v
Do not allow the thermal grease on the microprocessor and heat sink to come in
contact with anything. Contact with any surface can contaminate the thermal
grease and the microprocessor socket.
328
System x iDataPlex dx360 M4 Types 7912 and 7913: Problem Determination and Service Guide
Summary of Contents for System x iDataPlex dx360 M4 7912
Page 1: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 22: ...4 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 278: ...260 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 292: ...274 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 392: ...374 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 399: ......
Page 400: ...Part Number 46W8218 Printed in USA 1P P N 46W8218...