80070608-0a02ffff
Sensor [SensorElementName]
has transitioned to non-recoverable.
Explanation:
This message is for the use case when
an implementation has detected a Sensor transitioned
to non-recoverable.
Internal Event:
No
Severity:
Error
Alert Category:
Critical - Power
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0530
SNMP Trap ID:
4
Automatically notify Support:
No
User response:
If the specified sensor is PS n 12V
OC Fault, complete the following steps until the problem
is solved:
1.
Use the IBM Power Configurator utility to determine
current system power consumption. For more
information and to download the utility, go to
http://www-03.ibm.com/systems/bladecenter/
resources/powerconfig.html.
2.
Follow actions in "Power Problems and Solving
Power Problems".
If the specified sensor is PS n 12V OV Fault, complete
the following steps until the problem is solved:
1.
Check power supply n LED.
2.
Remove the failing power supply.
3.
(Trained technician only) Replace the system
board. (n = power supply number)
If the specified sensor is PS n 12V UV Fault, complete
the following steps until the problem is solved:
1.
Check power supply n LED.
2.
Remove the failing power supply.
3.
Follow actions in "Power Problems and Solving
Power Problems".
4.
(Trained technician only) Replace the system
board. (n = power supply number)
If the specified sensor is PS n 12Vaux Fault, complete
the following steps until the problem is solved:
1.
Check power supply n LED.
2.
Replace power supply n. (n = power supply
number)
80070614-2201ffff
Sensor [SensorElementName]
has transitioned to non-recoverable.
(TPM Phy Pres Set)
Explanation:
This message is for the use case when
an implementation has detected a Sensor transitioned
to non-recoverable.
Internal Event:
No
Severity:
Error
Alert Category:
Critical - Other
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0530
SNMP Trap ID:
50
Automatically notify Support:
No
User response:
1.
Update the server firmware (see Recovering the
server firmware).
2.
If the problem persists, (trained technician only)
replace the system board (see Removing the
system board and Installing the system board).
8008010f-2101ffff
Device
[LogicalDeviceElementName] has been
added. (Phy Presence Jmp)
Explanation:
This message is for the use case when
an implementation has detected a Device was inserted.
Internal Event:
No
Severity:
Info
Alert Category:
System - Other
Serviceable:
No
CIM Information: Prefix:
PLAT and
ID:
0536
SNMP Trap ID:
Automatically notify Support:
No
User response:
No action; information only.
80080128-2101ffff
Device
[LogicalDeviceElementName] has been
added. (Low Security Jmp)
Explanation:
This message is for the use case when
an implementation has detected a Device was inserted.
Internal Event:
No
Severity:
Info
Alert Category:
System - Other
Serviceable:
No
CIM Information: Prefix:
PLAT and
ID:
0536
SNMP Trap ID:
Automatically notify Support:
No
User response:
No action; information only.
80070608-0a02ffff • 80080128-2101ffff
70
System x iDataPlex dx360 M4 Types 7912 and 7913: Problem Determination and Service Guide
Summary of Contents for System x iDataPlex dx360 M4 7912
Page 1: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 22: ...4 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 278: ...260 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 292: ...274 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 392: ...374 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 399: ......
Page 400: ...Part Number 46W8218 Printed in USA 1P P N 46W8218...