800b0008-1301ffff
Redundancy
[RedundancySetElementName] has
been restored. (Power Unit)
Explanation:
This message is for the use case when
an implementation has detected Redundancy was
Restored.
Internal Event:
No
Severity:
Info
Alert Category:
Warning - Redundant Power Supply
Serviceable:
No
CIM Information: Prefix:
PLAT and
ID:
0561
SNMP Trap ID:
10
Automatically notify Support:
No
User response:
No action; information only.
800b0108-1301ffff
Redundancy Lost for
[RedundancySetElementName] has
asserted. (Power Unit)
Explanation:
This message is for the use case when
Redundancy Lost has asserted.
Internal Event:
No
Severity:
Error
Alert Category:
Critical - Redundant Power Supply
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0802
SNMP Trap ID:
9
Automatically notify Support:
No
User response:
1.
Check the LEDs for both power supplies.
2.
Follow the actions in Power-supply LEDs.
800b010a-1e81ffff
Redundancy Lost for
[RedundancySetElementName] has
asserted. (Cooling Zone)
Explanation:
This message is for the use case when
Redundancy Lost has asserted.
Internal Event:
No
Severity:
Error
Alert Category:
Critical - Fan Failure
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0802
SNMP Trap ID:
11
Automatically notify Support:
No
User response:
1.
Make sure that the connectors on fan n are not
damaged.
2.
Make sure that the fan n connectors on the system
board are not damaged.
3.
Make sure that the fans are correctly installed.
4.
Reseat the fans.
5.
Replace the fans. (n = fan number)
800b010c-2581ffff
Redundancy Lost for
[RedundancySetElementName] has
asserted. (Backup Memory)
Explanation:
This message is for the use case when
Redundancy Lost has asserted.
Internal Event:
No
Severity:
Error
Alert Category:
Critical - Memory
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0802
SNMP Trap ID:
41
Automatically notify Support:
No
User response:
1.
Check the system-event log for DIMM failure events
(uncorrectable or PFA) and correct the failures.
2.
Re-enable mirroring in the Setup utility.
800b030c-2581ffff
Non-redundant:Sufficient
Resources from Redundancy Degraded
or Fully Redundant for
[RedundancySetElementName] has
asserted. (Backup Memory)
Explanation:
This message is for the use case when
a Redundancy Set has transitioned from Redundancy
Degraded or Fully Redundant to Non-
redundant:Sufficient.
Internal Event:
No
Severity:
Warning
Alert Category:
Warning - Memory
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0806
SNMP Trap ID:
43
Automatically notify Support:
No
User response:
1.
Check the system-event log for DIMM failure events
(uncorrectable or PFA) and correct the failures.
2.
Re-enable mirroring in the Setup utility.
800b0008-1301ffff • 800b030c-2581ffff
Chapter 3. Diagnostics
71
Summary of Contents for System x iDataPlex dx360 M4 7912
Page 1: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 22: ...4 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 278: ...260 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 292: ...274 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 392: ...374 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 399: ......
Page 400: ...Part Number 46W8218 Printed in USA 1P P N 46W8218...