800b050a-1e81ffff
Non-redundant:Insufficient
Resources for
[RedundancySetElementName] has
asserted. (Cooling Zone)
Explanation:
This message is for the use case when
a Redundancy Set has transitioned to
Non-redundant:Insufficient Resources.
Internal Event:
No
Severity:
Error
Alert Category:
Critical - Fan Failure
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0810
SNMP Trap ID:
11
Automatically notify Support:
No
User response:
1.
Make sure that the connectors on fan n are not
damaged.
2.
Make sure that the fan n connectors on the system
board are not damaged.
3.
Make sure that the fans are correctly installed.
4.
Reseat the fans.
5.
Replace the fans. (n = fan number)
800b050c-2581ffff
Non-redundant:Insufficient
Resources for
[RedundancySetElementName] has
asserted. (Backup Memory)
Explanation:
This message is for the use case when
a Redundancy Set has transitioned to
Non-redundant:Insufficient Resources.
Internal Event:
No
Severity:
Error
Alert Category:
Critical - Memory
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0810
SNMP Trap ID:
41
Automatically notify Support:
No
User response:
1.
Check the system-event log for DIMM failure events
(uncorrectable or PFA) and correct the failures.
2.
Re-enable mirroring in the Setup utility.
806f0007-0301ffff
[ProcessorElementName] has
Failed with IERR. (CPU 1)
Explanation:
This message is for the use case when
an implementation has detected a Processor Failed -
IERR Condition.
Internal Event:
No
Severity:
Error
Alert Category:
Critical - CPU
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0042
SNMP Trap ID:
40
Automatically notify Support:
No
User response:
1.
Update the latest level of system firmware and
device drivers are installed for all adapters and
standard devices, such as UEFI, IMM Ethernet,and
SAS. Important: Some cluster solutions require
specific code levels or coordinated code updates. If
the device is part of a cluster solution, verify that the
latest level of code is supported for the cluster
solution before you update the code.
2.
Run the DSA program.
3.
Reseat the adapter.
4.
Replace the adapter.
5.
(Trained technician only) Replace microprocessor
n. (n = microprocessor number)
6.
(Trained technician only) Replace the system
board.
806f0007-0302ffff
[ProcessorElementName] has
Failed with IERR. (CPU 2)
Explanation:
This message is for the use case when
an implementation has detected a Processor Failed -
IERR Condition.
Internal Event:
No
Severity:
Error
Alert Category:
Critical - CPU
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0042
SNMP Trap ID:
40
Automatically notify Support:
No
User response:
1.
Update the latest level of system firmware and
device drivers are installed for all adapters and
standard devices, such as UEFI, IMM Ethernet,and
SAS. Important: Some cluster solutions require
specific code levels or coordinated code updates. If
the device is part of a cluster solution, verify that the
latest level of code is supported for the cluster
solution before you update the code.
2.
Run the DSA program.
3.
Reseat the adapter.
4.
Replace the adapter.
800b050a-1e81ffff • 806f0007-0302ffff
72
System x iDataPlex dx360 M4 Types 7912 and 7913: Problem Determination and Service Guide
Summary of Contents for System x iDataPlex dx360 M4 7912
Page 1: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 22: ...4 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 278: ...260 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 292: ...274 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 392: ...374 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 399: ......
Page 400: ...Part Number 46W8218 Printed in USA 1P P N 46W8218...