1. Orient the cover over the rear of the chassis so that the retention tabs on the
cover align with the tabs in the chassis.
2. Slide the cover onto the chassis until the cover-release buttons click into place.
3. Install the chassis in the rack (see “Installing the 2U chassis in a rack” on page
Removing the 2U chassis from a rack
To remove the 2U chassis from a rack, complete the following steps.
1. Read the safety information that begins on page vii and “Installation guidelines”
2. If the chassis contains a system-board tray that is operating, shut down the
operating system; then, press the power-control button to turn off the
system-board tray (see “Turning off the system-board tray” on page 11 for more
information).
3. Remove external cables.
4. Remove any installed system-board trays (see “Removing the system-board tray
from a 2U chassis” on page 279).
5. If the iDataPlex does not equip with the rail having power cord retention feature,
remove power cords.
6. Loosen the two screws that secure the chassis, slide the chassis out.
7. Set it on a flat, static-protective surface.
8. If you are replacing a damaged chassis, remove the fan assembly and power
supply cage from the chassis, and place them on a static-protective surface or
install them in the new chassis (see “Removing the 2U chassis fan assembly”
on page 289 and “Removing a power supply from a 2U chassis” on page 315).
9. If you are instructed to return the 2U chassis, follow all packaging instructions,
and use any packaging materials for shipping that are supplied to you.
284
System x iDataPlex dx360 M4 Types 7912 and 7913: Problem Determination and Service Guide
Summary of Contents for System x iDataPlex dx360 M4 7912
Page 1: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 22: ...4 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 278: ...260 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 292: ...274 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 392: ...374 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 399: ......
Page 400: ...Part Number 46W8218 Printed in USA 1P P N 46W8218...