c. Use your thumb and index finger to lift the battery from the socket.
Attention:
Do not lift the battery by using excessive force. Failing to remove
the battery properly may damage the socket on the system board. Any damage
to the socket may require replacing the system board.
9. Dispose of the battery as required by local ordinances or regulations. See the
IBM Environmental Notices and User's Guide
on the IBM
System x
Documentation
CD for more information.
Installing the system battery
The following notes describe information that you must consider when replacing the
system-board battery in the server.
v
When replacing the system-board battery, you must replace it with a lithium
battery of the same type from the same manufacturer.
v
To order replacement batteries, call 1-800-426-7378 within the United States, and
1-800-465-7999 or 1-800-465-6666 within Canada. Outside the U.S. and
Canada, call your IBM marketing representative or authorized reseller.
v
After you replace the system-board battery, you must reconfigure the server and
reset the system date and time.
v
To avoid possible danger, read and follow the following safety statement.
Statement 2:
CAUTION:
When replacing the lithium battery, use only IBM Part Number 33F8354 or an
equivalent type battery recommended by the manufacturer. If your system has
a module containing a lithium battery, replace it only with the same module
type made by the same manufacturer. The battery contains lithium and can
explode if not properly used, handled, or disposed of.
Do not:
v
Throw or immerse into water
v
Heat to more than 100°C (212°F)
v
Repair or disassemble
Dispose of the battery as required by local ordinances or regulations.
To install the replacement system-board battery, complete the following steps:
1. Follow any special handling and installation instructions that come with the
replacement battery.
292
System x iDataPlex dx360 M4 Types 7912 and 7913: Problem Determination and Service Guide
Summary of Contents for System x iDataPlex dx360 M4 7912
Page 1: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 22: ...4 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 278: ...260 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 292: ...274 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 392: ...374 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 399: ......
Page 400: ...Part Number 46W8218 Printed in USA 1P P N 46W8218...