User response:
Complete the following steps:
1.
If a DIMM connector error LED is lit, resolve the
failure.
2.
Make sure that the DIMM connectors are correctly
populated for mirroring mode, according to the
service information for this product.
W.580A2
[W.580A2] Invalid memory
configuration for Sparing Mode. Please
correct memory configuration.
Explanation:
Unsupported DIMM Population for Spare
Mode
Severity:
Error
User response:
Complete the following steps:
1.
Make sure that the DIMM connectors are correctly
populated for sparing mode, according to the service
information for this product.
W.68002
[W.68002] A CMOS battery error has
been detected
Explanation:
CMOS Battery Fault
Severity:
Error
User response:
Complete the following steps:
1.
If the system was recently Installed, Moved, or
Serviced, makesure the batter is properly seated.
2.
Check IBM support site for an applicable service
bulletin or firmware update that applies to this error.
3.
Replace CMOS Battery
4.
(Trained Service technician only) Replace the
system board.
System event log
The system event log contains messages of three types:
Information
Information messages do not require action; they record significant
system-level events, such as when the server is started.
Warning
Warning messages do not require immediate action; they indicate possible
problems, such as when the recommended maximum ambient temperature
is exceeded.
Error
Error messages might require action; they indicate system errors, such as
when a fan is not detected.
Each message contains date and time information, and it indicates the source of
the message (POST or the IMM2).
Integrated management module II (IMM2) error messages
The following table describes the IMM2 error messages and suggested actions to
correct the detected problems.
For more information about IMM2, see the
Integrated Management Module II User's
Guide
at http://www.ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-
40000001-00000000
Management Controller [arg1]
Network Initialization Complete.
Explanation:
This message is for the use case where
a Management Controller network has completed
initialization.
Internal Event:
No
Severity:
Info
Alert Category:
System - IMM Network event
Serviceable:
No
CIM Information: Prefix:
IMM and
ID:
0001
SNMP Trap ID:
37
Automatically notify Support:
No
User response:
Information only; no action is
required.
40000002-00000000
Certificate Authority [arg1] has
detected a [arg2] Certificate Error.
Explanation:
This message is for the use case when
W.580A2 • 40000002-00000000
30
System x iDataPlex dx360 M4 Types 7912 and 7913: Problem Determination and Service Guide
Summary of Contents for System x iDataPlex dx360 M4 7912
Page 1: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 22: ...4 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 278: ...260 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 292: ...274 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 392: ...374 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 399: ......
Page 400: ...Part Number 46W8218 Printed in USA 1P P N 46W8218...