background image

Microprocessors

 

v

   

Are

 

microprocessor

 

upgrades

 

available

 

for

 

the

 

iDataPlex

 

dx360?

 

Microprocessor

 

upgrades

 

are

 

not

 

available

 

for

 

the

 

iDataPlex

 

dx360

 

servers.

 

The

 

microprocessors

 

are

 

field

 

replaceable

 

units

 

(FRUs).

 

FRUs

 

must

 

be

 

installed,

 

removed,

 

or

 

replaced

 

only

 

by

 

trained

 

service

 

technicians.

 

v

   

What

 

microprocessors

 

are

 

available

 

for

 

the

 

iDataPlex

 

dx360?

 

The

 

iDataPlex

 

dx360

 

system

 

board

 

supports

 

two

 

dual-core

 

or

 

quad-core

 

Intel

 

Xeon

 

microprocessors.

 

As

 

of

 

the

 

date

 

of

 

this

 

publication,

 

the

 

following

 

microprocessors

 

are

 

available

 

for

 

the

 

iDataPlex

 

dx360

 

system

 

board:

 

   

Intel

 

Xeon

 

L5410

 

2.33

 

GHz/1333

 

MHz

 

quad

 

core

 

50W

 

   

Intel

 

Xeon

 

L5420

 

2.50

 

GHz/1333

 

MHz

 

quad

 

core

 

50W

 

   

Intel

 

Xeon

 

E5420

 

2.50

 

GHz/1333

 

MHz

 

quad

 

core

 

80W

 

   

Intel

 

Xeon

 

E5430

 

2.66

 

GHz/1333

 

MHz

 

quad

 

core

 

80W

 

   

Intel

 

Xeon

 

E5462

 

2.80

 

GHz/1600

 

MHz

 

quad

 

core

 

80W

 

   

Intel

 

Xeon

 

E5440

 

2.83

 

GHz/1333

 

MHz

 

quad

 

core

 

80W

 

   

Intel

 

Xeon

 

L5240

 

3.00

 

GHz/1333

 

MHz

 

dual

 

core

 

40W

 

   

Intel

 

Xeon

 

E5472

 

3.00

 

GHz/1600

 

MHz

 

quad

 

core

 

80W

Operating

 

systems

 

   

What

 

operating

 

systems

 

are

 

supported

 

for

 

the

 

iDataPlex

 

dx360?

 

As

 

of

 

the

 

date

 

of

 

this

 

publication,

 

the

 

iDataPlex

 

dx360

 

servers

 

support

 

Red

 

Hat

 

Enterprise

 

Linux

®

 

5.1

 

and

 

SUSE

 

Linux

 

Enterprise

 

Server

 

(SLES)

 

10.1.

 

For

 

up-to-date

 

information

 

about

 

the

 

operating

 

systems

 

supported

 

for

 

the

 

iDataPlex

 

dx360,

 

contact

 

your

 

IBM

 

marketing

 

representative

 

or

 

authorized

 

reseller.

Passwords

 

and

 

security

 

v

   

Why

 

did

 

the

 

iDataPlex

 

dx360

 

server

 

stop

 

working

 

and

 

display

 

the

 

message

 

Invalid

 

Password

?

 

The

 

iDataPlex

 

dx360

 

server

 

will

 

stop

 

operating

 

when

 

an

 

incorrect

 

power-on

 

password

 

is

 

entered

 

three

 

consecutive

 

times.

 

You

 

can

 

regain

 

access

 

to

 

the

 

dx360

 

server

 

in

 

any

 

of

 

the

 

following

 

ways:

 

   

If

 

an

 

administrator

 

password

 

is

 

set,

 

type

 

the

 

administrator

 

password

 

at

 

the

 

password

 

prompt.

 

Start

 

the

 

BIOS

 

Setup

 

Utility

 

program

 

and

 

reset

 

the

 

user

 

password.

 

   

Clear

 

the

 

password

 

by

 

using

 

the

 

clear

 

jumper.

 

(See

 

the

 

IBM

 

System

 

x

 

iDataPlex

 

dx360

 

Problem

 

Determination

 

and

 

Service

 

Guide

 

for

 

instructions.)

v

   

Why

 

are

 

all

 

users

 

allowed

 

to

 

connect

 

to

 

the

 

iDataPlex

 

dx360

 

with

 

an

 

IPMI

 

command?

 

The

 

iDataPlex

 

dx360

 

is

 

shipped

 

with

 

no

 

configured

 

password.

 

When

 

the

 

iDataPlex

 

dx360

 

is

 

installed,

 

the

 

customer

 

must

 

set

 

the

 

password

 

and

 

authentication

 

level

 

if

 

they

 

want

 

to

 

restrict

 

access

 

to

 

the

 

server.

 

 

Chapter

 

2.

 

Hints

 

and

 

tips

 

9

Summary of Contents for System x iDataPlex dx360

Page 1: ...System x iDataPlex dx360 FAQ for Types 6313 6316 6385 6390 7831 and 7833 Hints and Tips...

Page 2: ......

Page 3: ...System x iDataPlex dx360 FAQ for Types 6313 6316 6385 6390 7831 and 7833 Hints and Tips...

Page 4: ...s read the general information in Notices on page 13 First Edition November 2008 Copyright International Business Machines Corporation 2008 US Government Users Restricted Rights Use duplication or dis...

Page 5: ...guration 7 IP settings and alerts 7 Management tools 8 Memory 8 Microprocessors 9 Operating systems 9 Passwords and security 9 System error LED 10 Video 10 Chapter 3 Getting help and technical assista...

Page 6: ...iv IBM System x iDataPlex dx360 Hints and Tips...

Page 7: ...ex dx360 Types 6313 6316 6385 6390 7831 and 7833 User s Guide This document contains general information about how to use upgrade and configure the 2U chassis the dx360 system board tray and the Syste...

Page 8: ...rmation and technical updates go to http publib boulder ibm com infocenter systems scope idataplex index jsp The updated iDataPlex documentation also is available from the IBM Support Web site To chec...

Page 9: ...er with 32 MB DDR2 SDRAM v Dual 10 Mb 100 Mb 1 GB network interface controllers v Wake on LAN support v I O Controller with six Serial ATA SATA ports v Front panel connectors Two Universal Serial Bus...

Page 10: ...mponents The following illustration shows the major components in the dx360 system board tray Note The illustrations in this document might differ slightly from your hardware 4 IBM System x iDataPlex...

Page 11: ...is as follows 1 Hard disk drive boot 2 Network boot 3 Unified Extensible Firmware Interface UEFI boot v How can I change the iDataPlex dx360 boot order You can use the BIOS Setup Utility to change or...

Page 12: ...de Firmware updates v Can I update just the BIOS The firmware update package contains the BIOS and BMC code When you install the package it automatically updates the BIOS and BMC code simultaneously T...

Page 13: ...rver consists of a dx360 system board tray with a storage enclosure installed in a 2U chassis The storage enclosure provides four additional 3 5 inch drive bays and enables the server to have up to fo...

Page 14: ...did 16923 stross all osfullname all 20operating 20systems lang eng Memory v Are memory upgrades available for the iDataPlex dx360 Memory upgrades are not available for the iDataPlex dx360 servers To a...

Page 15: ...Plex dx360 As of the date of this publication the iDataPlex dx360 servers support Red Hat Enterprise Linux 5 1 and SUSE Linux Enterprise Server SLES 10 1 For up to date information about the operating...

Page 16: ...error LED will be lit Also after you complete a repair or correct an error clear the BMC system event log to turn off the system error LED Video Why does the video take so long to appear during startu...

Page 17: ...ur IBM product The documentation that comes with IBM systems also describes the diagnostic tests that you can perform Most systems operating systems and programs come with documentation that contains...

Page 18: ...http www ibm com services sl products For more information about Support Line and other IBM services see http www ibm com services or see http www ibm com planetwide for support telephone numbers In t...

Page 19: ...10504 1785 U S A INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES...

Page 20: ...stems Incorporated in the United States other countries or both UNIX is a registered trademark of The Open Group in the United States and other countries Java and all Java based trademarks are tradema...

Page 21: ...drive capacities assume the replacement of any standard hard disk drives and population of all hard disk drive bays with the largest currently supported drives that are available from IBM Maximum memo...

Page 22: ...16 IBM System x iDataPlex dx360 Hints and Tips...

Page 23: ...orted 7 hardware service and support 12 help getting 11 humidity 3 I IBM Support Line 12 iDataPlex Information Center URL 2 11 illustration system board tray 4 initialization video 10 integrated funct...

Page 24: ...nfig 8 trademarks 14 U UEFI boot 5 updated documentation 2 upgrades memory 8 microprocessor 9 URL IBM support site 6 iDataPlex Information Center 2 11 IPMItool 8 sysconfig tool 8 XCAT tool 8 V video i...

Page 25: ......

Page 26: ...Part Number 46M1463 Printed in USA 1P P N 46M1463...

Reviews: