Features and specifications
The following information is a summary of the features and specifications of the
hardware. Depending on the hardware configuration, some features might not be
available, or some specifications might not apply.
Racks are marked in vertical increments of 4.45 cm (1.75 inches). Each increment
is referred to as a unit, or “U.” A 1U-high device is 1.75 inches tall.
Table 1. Features and specifications
Microprocessor:
Supports two
dual-core or quad-core Intel Xeon
microprocessors in each system-board
tray
Note:
Use the BIOS Setup Utility
program to determine the type and
speed of the microprocessor.
Memory:
v
Four-channel DIMMs: 16 DIMM
connectors
v
Types: Fully buffered double-data
rate (DDR2) 667 MHz DIMMs with
AMB+ or DDR2 800 MHz DIMMs
with AMB+
v
Supports 2 GB and 4 GB DIMMs
(as of the date of this publication)
with up to 64 GB of total memory in
each system-board tray
Hard disk drives:
v
The system-board tray supports
one 3.5-inch simple-swap SAS or
one 3.5-inch simple-swap SATA
hard disk drive.
v
The system-board tray with a
storage enclosure attached can
support up to four 3.5-inch
simple-swap SAS hard disk drives
or up to five 3.5-inch simple-swap
SATA hard disk drives.
PCI expansion slots:
v
Each system-board tray supports
one PCIe expansion slot
Integrated functions:
v
Intel baseboard management
controller (BMC) with Intelligent
Platform Management Interface
(IPMI) 2.0 compliant firmware
v
ATI ES1000 video controller with
32 MB DDR2 SDRAM
v
Dual 10 Mb/100 Mb/1 GB network
interface controllers
v
Wake on LAN support
v
I/O Controller with six Serial ATA
(SATA) ports
v
Front panel connectors:
– Two Universal Serial Bus
(USB) 2.0 ports
– One systems management
serial port
– VGA
video
port
– Two Ethernet ports
Size (2U chassis):
v
Height: 86 mm (3.386 inches)
v
Depth: 473 mm (18.6 inches)
v
Width: 446 mm (17.56 inches)
v
Maximum weight: 6.98 kg (15.5 lb)
Environment:
v
Air temperature:
– Server on: 10°C to 35°C (50°F to
95°F); altitude: 0 to 914.4 m (0 to
3000 ft). Derate maximum
temperature by 1°C for every
304.8 m (1000 ft) increase in
elevation to a maximum of
3,048.0 m (10000 ft) at an
ambient temperature of 28°C.
– Server off: 10°C to 43°C (59°F to
109.4°F); maximum altitude: 2133
m (7000 ft)
v
Humidity:
– Server on: 10% to 80%
– Server off: 8% to 80%
Electrical Input:
v
Input voltage low range: 100 V ac
(minimum) to 127 V ac (maximum),
50 to 60 Hz, sine-wave input
v
Input voltage high range: 200 V ac
(minimum) to 240 V ac (maximum),
50 to 60 Hz, sine-wave input
Chapter 1. Introduction
5
Summary of Contents for System x iDataPlex dx360
Page 1: ...System x iDataPlex dx360 Types 6313 6316 6385 6390 7831 and 7833 User s Guide...
Page 2: ......
Page 3: ...System x iDataPlex dx360 Types 6313 6316 6385 6390 7831 and 7833 User s Guide...
Page 11: ...Statement 10 CAUTION Do not place any object on top of rack mounted devices Safety ix...
Page 12: ...x IBM iDataPlex dx360 User s Guide...
Page 46: ...34 IBM iDataPlex dx360 User s Guide...
Page 54: ...42 IBM iDataPlex dx360 User s Guide...
Page 67: ......
Page 68: ...Part Number 90Y5678 Printed in USA 1P P N 90Y5678...