When you install or remove DIMMs, the server configuration information
changes. When you restart the server, the system displays a message that
indicates that the memory configuration has changed.
v
The specifications of a DDR3 DIMM are on a label on the DIMM, in the following
format.
ggg e
Rx
ff
-PC3-
wwwwwm
-
aa
-
bb
-
cc
where:
ggg
is the total capacity of the DIMM (for example, 1GB, 2GB, or 4GB)
e
is the number of ranks
1 = single-rank
2 = dual-rank
4 = quad-rank
ff
is the device organization (bit width)
4 = x4 organization (4 DQ lines per SDRAM)
8 = x8 organization
16 = x16 organization
wwwww
is the DIMM bandwidth, in MBps
8500 = 8.53 GBps (PC3-1066 SDRAMs, 8-byte primary data bus)
10600 = 10.66 GBps (PC3-1333 SDRAMs, 8-byte primary data bus)
m
is the DIMM type
E = Unbuffered DIMM (UDIMM) with ECC (x72-bit module data bus)
R = Registered DIMM (RDIMM)
U = Unbuffered DIMM with no ECC (x64-bit primary data bus)
aa
is the CAS latency, in clocks at maximum operating frequency
bb
is the JEDEC SPD Revision Encoding and Additions level
cc
is the reference design file for the design of the DIMM
d
is the revision number of the reference design of the DIMM
Note:
To determine the type of a DIMM, see the label on the DIMM. The
information on the label is in the format xxxxx nRxxx PC3-xxxxx-xx-xx-xxx. The
numeral in the sixth numerical position indicates whether the DIMM is single-rank
(n=1) or dual-rank (n=2).
The following sections provide additional information specific to unbuffered and
registered DIMMs that you must consider.
Unbuffered DIMMs (UDIMMs)
The following notes provide information that you must consider when you install
UDIMMs:
v
The memory channels run at the lowest common frequency of the DIMMs
installed.
v
The UDIMM options that are available for the server are 1 GB, 2 GB, 4 GB, and
8 GB (when available) DIMMs.
v
The server supports up to two single-rank or dual-rank UDIMMs per channel.
v
The following table lists the supported UDIMM population.
Chapter 2. Installing optional devices
29
Summary of Contents for System x3100 M4
Page 1: ...System x3100 M4 Type 2582 Installation and User s Guide...
Page 2: ......
Page 3: ...System x3100 M4 Type 2582 Installation and User s Guide...
Page 8: ...vi System x3100 M4 Type 2582 Installation and User s Guide...
Page 18: ...xvi System x3100 M4 Type 2582 Installation and User s Guide...
Page 90: ...72 System x3100 M4 Type 2582 Installation and User s Guide...
Page 100: ...82 System x3100 M4 Type 2582 Installation and User s Guide...
Page 106: ...88 System x3100 M4 Type 2582 Installation and User s Guide...
Page 107: ......
Page 108: ...Part Number 00D3167 Printed in USA 1P P N 00D3167...