6. Remove the air duct.
7. Remove the simple-swap hard disk drives (see “Removing a simple-swap hard
disk drive” on page 194).
8. Remove the simple-swap backplate (see “Removing the simple-swap
backplate” on page 217).
9. Press and hold the drive cage release latches.
Cage release latches
10. Carefully pull the hard disk drive cage and the cables out of the opening in the
chassis.
11. If you are instructed to return the drive cage, follow all packaging instructions,
and use any packaging materials for shipping that are supplied to you.
Installing the hard disk drive cage
This procedure applies only to 4U server models with non-hot-swap power supplies.
To install the hard disk drive cage on 4U server models with non-hot-swap power
supplies, complete the following steps.
1. Read the safety information that begins on page vii and “Installation guidelines”
on page 163.
2. Turn off the server and all attached devices; then, disconnect all power cords
and external cables.
3. Remove the bezel (see “Removing the bezel” on page 169).
4. Carefully turn the server on its side so that it is lying flat, with the cover facing
up.
Attention:
Do not allow the server to fall over.
5. Remove the side cover (see “Removing the side cover” on page 166).
6. Remove the air duct.
7. Press hard disk drive cage in until the release latches click into place.
238
IBM System x3100 M4 Type 2582: Problem Determination and Service Guide
Summary of Contents for System x3100 M4
Page 1: ...IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 24: ...4 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 42: ...22 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 170: ...150 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 182: ...162 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 286: ...266 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 316: ...296 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 324: ...304 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 331: ......
Page 332: ...Part Number 00V9701 Printed in USA 1P P N 00V9701...