Error code
Description
Action
305000A
Date, time, or both are incorrect.
1. Run the Setup utility (see “Using the Setup utility”
on page 271), select
Load Default Settings
, and
save the settings.
2. Replace the CMOS battery (see “Removing the
system battery” on page 207 and “Installing the
system battery” on page 209).
3. Replace the battery.
3058004
Three boot failure
1. Undo any recent system changes, such as new
settings or newly installed devices.
2. Make sure that the server is attached to a reliable
power source.
3. Remove all hardware that is not listed on the
ServerProven web site at http://www.ibm.com/
servers/eserver/serverproven/compat/us/.
4. Update the firmware to the latest level
(see“Updating the firmware” on page 267 for more
information).
5. Make sure that the operating system is not
corrupted.
6. Run the Setup utility, save the configuration, and
then restart the server.
7. (Trained service technician only) If the problem
remains, replace the system board (see“Removing
the system board” on page 258 and “Installing the
system board” on page 261).
3808000
IMM2 communication failure
1. Shut down the system and remove the power
cords from the server for 30 seconds; then,
reconnect the server to power and restart it.
2. Update the IMM2 firmware to the latest level (see
“Updating the firmware” on page 267).
3. (Trained service technician only) Replace the
system board (see“Removing the system board”
on page 258 and “Installing the system board” on
page 261).
3808002
Configuration update to IMM2 failed.
1. Run the Setup utility, select
Save Settings
, and
restart the server (see “Using the Setup utility” on
page 271).
2. Update the IMM2 firmware to the latest level (see
“Updating the firmware” on page 267).
Chapter 3. Diagnostics
37
Summary of Contents for System x3100 M4
Page 1: ...IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 24: ...4 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 42: ...22 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 170: ...150 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 182: ...162 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 286: ...266 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 316: ...296 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 324: ...304 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 331: ......
Page 332: ...Part Number 00V9701 Printed in USA 1P P N 00V9701...