Table 6. IMM2 error messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
806f0107-0301xxxx
The Processor CPU
Status has been
detected an
over-temperature
condition.
Error
An over
temperature
condition has
occurred.
1. Make sure that the latest levels of
firmware and device drivers are
installed for all adapters and
standard devices, such as
Ethernet, SCSI, and SAS.
Important:
Some cluster solutions
require specific code levels or
coordinated code updates. If the
device is part of a cluster solution,
verify that the latest level of code
is supported for the cluster solution
before you update the code.
2. Update the firmware (UEFI and
IMM2) to the latest level (see
“Updating the firmware” on page
267).
3. Run the DSA program.
4. Reseat the adapter (see
“Removing a ServeRAID adapter”
on page 176 and “Installing a
ServeRAID adapter” on page 178).
5. Replace the adapter.
6. (Trained technician only) Replace
microprocessor (see “Removing
the microprocessor and heat sink”
on page 250 and “Installing a
microprocessor and heat sink” on
page 254).
7. (Trained technician only) Replace
the system board (see “Removing
the system board” on page 258
and “Installing the system board”
on page 261).
806f0207-0301xxxx
The Processor CPU
Status has Failed with
BIST condition.
Error
A processor failed
- BIST condition
has occurred.
1. Make sure that the fans are
operating. There are no
obstructions to the airflow (front
and rear of the server), the air
baffles are in place and correctly
installed, and the server cover is
installed and completely closed.
2. Make sure that the heat sink for
microprocessor is installed
correctly.
3. (Trained service technician only)
Replace microprocessor (see
“Removing the microprocessor and
heat sink” on page 250 and
“Installing a microprocessor and
heat sink” on page 254).
Chapter 3. Diagnostics
43
Summary of Contents for System x3100 M4
Page 1: ...IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 24: ...4 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 42: ...22 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 170: ...150 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 182: ...162 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 286: ...266 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 316: ...296 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 324: ...304 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 331: ......
Page 332: ...Part Number 00V9701 Printed in USA 1P P N 00V9701...