Table 19. DSA messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
v
Go to the IBM support web site at http://www.ibm.com/supportportal/ to check for technical information,
hints, tips, and new device drivers or to submit a request for information.
Message
number
Component Test
State
Description
Action
166-905-xxx
IMM
IMM I
2
C
Test
Failed
IMM Indicates
failure in the
PIC 16F887
(Power Paddle
Card) bus (BUS
4).
1.
Turn off the system and disconnect it
from the power source. You must
disconnect the system from ac power to
reset the IMM2.
2.
After 45 seconds, reconnect the system to
the power source and turn on the system.
3.
Make sure that the DSA code is at the
latest level. For the latest level of DSA
code, go to http://www.ibm.com/
support/docview.wss?uid=psg1SERV-
DSA.
4.
Make sure that the IMM2 firmware is at
the latest level. The installed firmware
level is shown in the DSA event log in the
Firmware/VPD section for this
component. For more information, see
“Updating the firmware” on page 111.
5.
Run the test again.
6.
If the failure remains, go to the IBM Web
site for more troubleshooting information
at http://www.ibm.com/support/
docview.wss?uid=psg1SERV-OPTN.
166-907-xxx
IMM
IMM I
2
C
Test
Failed
IMM Indicates
failure in the
LM75 (Thermal
Sensor) bus
(BUS 6).
1.
Turn off the system and disconnect it
from the power source. You must
disconnect the system from ac power to
reset the IMM2.
2.
After 45 seconds, reconnect the system to
the power source and turn on the system.
3.
Make sure that the DSA code is at the
latest level. For the latest level of DSA
code, go to http://www.ibm.com/
support/docview.wss?uid=psg1SERV-
DSA.
4.
Make sure that the IMM2 firmware is at
the latest level. The installed firmware
level is shown in the DSA event log in the
Firmware/VPD section for this
component. For more information, see
“Updating the firmware” on page 111.
5.
Run the test again.
6.
If the failure remains, go to the IBM Web
site for more troubleshooting information
at http://www.ibm.com/support/
docview.wss?uid=psg1SERV-OPTN.
Chapter 4. Troubleshooting
257
Summary of Contents for System x3300 M4
Page 1: ...System x3300 M4 Type 7382 Installation and Service Guide...
Page 2: ......
Page 3: ...System x3300 M4 Type 7382 Installation and Service Guide...
Page 8: ...vi System x3300 M4 Type 7382 Installation and Service Guide...
Page 18: ...xvi System x3300 M4 Type 7382 Installation and Service Guide...
Page 44: ...26 System x3300 M4 Type 7382 Installation and Service Guide...
Page 128: ...110 System x3300 M4 Type 7382 Installation and Service Guide...
Page 156: ...138 System x3300 M4 Type 7382 Installation and Service Guide...
Page 382: ...364 System x3300 M4 Type 7382 Installation and Service Guide...
Page 405: ...Chapter 6 Removing and replacing components 387...
Page 450: ...432 System x3300 M4 Type 7382 Installation and Service Guide...
Page 454: ...436 System x3300 M4 Type 7382 Installation and Service Guide...
Page 468: ...450 System x3300 M4 Type 7382 Installation and Service Guide...
Page 469: ......
Page 470: ...Part Number 00V9709 Printed in USA 1P P N 00V9709...