background image

IBM System x3650 M4 HD

3

Availability and serviceability

The x3650 M4 HD provides many features to simplify serviceability and increase system uptime: 

The server offers memory mirroring and memory rank sparing for redundancy in the event of a 

non-correctable memory failure.
Tool-less cover removal provides easy access to upgrades and serviceable parts, such as CPU, 

memory, and adapters.
The server offers hot-swap drives, supporting RAID redundancy for data protection and greater 

system uptime.
The server has up to two redundant hot-swap power supplies and four hot-swap dual-motor redundant 

fans (two fan zones with an N+1 fan design) to provide availability for business-critical applications.
A light path diagnostics panel and individual light path LEDs quickly lead the technician to failed (or 

failing) components, which simplifies servicing, speeds up problem resolution, and helps improve 

system availability.
Predictive Failure Analysis (PFA) detects when system components (processors, VRMs, memory, 

HDDs, fans, and power supplies) operate outside of standard thresholds and generates proactive 

alerts in advance of a possible failure, therefore increasing uptime.
SSDs offer better reliability than traditional HDDs for greater uptime.

The built-in Integrated Management Module Version II (IMM2) continuously monitors system 

parameters, triggers alerts, and performs recovery actions in case of failures to minimize downtime.
Built-in diagnostics, using Dynamic Systems Analysis (DSA) Preboot, speed up troubleshooting tasks 

to reduce service time.
Three-year customer-replaceable unit and onsite limited warranty, 9x5 next business day. Optional 

service upgrades are available.

Manageability and security

Powerful systems management features simplify local and remote management of the x3650 M4 HD:

Local console ports are standard at the rear of the server. Front video and USB ports are available 

through an optional console breakout cable.
The server includes an Integrated Management Module II (IMM2) to monitor server availability and 

perform remote management.
An Integrated industry-standard Unified Extensible Firmware Interface (UEFI) enables improved 

setup, configuration, and updates, and simplifies error handling.
Integrated Trusted Platform Module (TPM) 1.2 support enables advanced cryptographic functionality, 

such as digital signatures and remote attestation.
Industry-standard Advanced Encryption Standard (AES) NI support for faster, stronger encryption.

IBM Systems Director is included for proactive systems management. It offers comprehensive 

systems management tools that help increase uptime, reduce costs, and improve productivity through 

advanced server management capabilities.
Intel Execute Disable Bit functionality can prevent certain classes of malicious buffer overflow attacks 

when combined with a supported operating system.
Intel Trusted Execution Technology provides enhanced security through hardware-based resistance 

to malicious software attacks, allowing an application to run in its own isolated space, protected from 

all other software running on a system.

Summary of Contents for System x3650 M4 HD

Page 1: ...uting deployments data management and business critical workloads The following figure shows the IBM System x3650 M4 HD configured with 24 hot swap 2 5 inch drive bays Figure 1 The IBM System x3650 M4...

Page 2: ...l Hyper Threading Technology boosts performance for multi threaded applications by enabling simultaneous multi threading within each processor core up to two threads per core Intel Virtualization Tech...

Page 3: ...stics using Dynamic Systems Analysis DSA Preboot speed up troubleshooting tasks to reduce service time Three year customer replaceable unit and onsite limited warranty 9x5 next business day Optional s...

Page 4: ...s needed to reduce power draw Low voltage Intel Xeon processors draw less energy to satisfy the demands of power and thermally constrained data centers and telecommunication environments Low voltage 1...

Page 5: ...he following figure shows the rear of the server Figure 3 Rear view of the IBM System x3650 M4 HD The following figure shows the locations of key components inside the server Figure 4 Inside view of t...

Page 6: ...16x 2 5 inch HDDs SSDs front plus 16x 1 8 inch SSDs front accessible Maximum internal storage Up to 26 TB with 26x 1 TB NL SAS HDDs Up to 16 TB HDD storage with 16x 1 TB NL SAS HDDs 8 TB SSD storage...

Page 7: ...IBM ServerGuide Optional IMM Advanced Upgrade software feature for remote presence Security features Power on password administrator s password and Trusted Platform Module TPM Operating systems suppo...

Page 8: ...460 H3x 1x E5 2660 v2 10C 2 2GHz 25MB 1866MHz 95W 1x 8 GB 1866 MHz M5210 e H1110 16 2x 2 5 Open 1 0 4 4 1x 750W 5460 J3x 1x E5 2670 v2 10C 2 5GHz 25MB 1866MHz 115W 1x 16 GB 1866 MHz M5210 e 16x 2 5 Op...

Page 9: ...Flash R5 16x 2 5 Open 3 3 6 4 1x 750W Central and Eastern Europe CEE and Middle East and Africa MEA 5460 E1G 1x E5 2620 v2 6C 2 1GHz 15MB 1600MHz 80W 1x 8 GB 1600 MHz M5210 e 1GB Flash R5 16x 2 5 Open...

Page 10: ...on E5 2650 v2 8C 2 6GHz 20MB 1866MHz 95W G3x 46W4225 A3Q8 A3RZ Intel Xeon E5 2650L v2 10C 1 7GHz 25MB 1600MHz 70W 46W4216 A3PZ A3RQ Intel Xeon E5 2660 v2 10C 2 2GHz 25MB 1866MHz 95W H3x 46W4222 A3Q5 A...

Page 11: ...under the Maximum operating speed section in Table 5 The following table Parts 1 and 2 shows the characteristics of the supported DIMMs Tables cells that are highlighted with a gray background indicat...

Page 12: ...hannel No support No support 1066 MHz The maximum quantity that is supported is shown for two processors installed The following memory protection technologies are supported ECC Chipkill for x4 based...

Page 13: ...CL13 ECC DDR3 1866MHz LP RDIMM 24 12 per CPU G3x H3x 00D5040 A3QJ 8GB 1x8GB 2Rx8 1 5V PC3 14900 CL13 ECC DDR3 1866MHz LP RDIMM 24 12 per CPU 83x J3x L3x M3x 00D5048 A3QL 16GB 1x16GB 2Rx4 1 5V PC3 149...

Page 14: ...t swap drive bays rear 24x 2 5 inch hot swap drive bays front 24x 2 5 inch hot swap drive bays front 2x 2 5 inch hot swap drive bays rear 16x 2 5 inch hot swap drive bays front 16x 1 8 inch hot swap d...

Page 15: ...3NR A4M4 A4M6 and A4M7 but not A4M5 The following table shows the internal storage expansion options that are available for the x3650 M4 HD server Table 8 Internal storage expansion options Part 1 Con...

Page 16: ...lanes with M5210e Two 8 bay 1 8 inch backplanes Each 1 8 in backplane connects to an M5210 or N2215 adapter Adapters are not part of feature A4M5 x3650 M4 HD Rear 2 HDD Kit feature A3NQ Add on for Opt...

Page 17: ...3 ServeRAID M5200 Series 4GB Flash RAID 5 Upgrade 1 Feature on Demand upgrades for the M5210 and M5210e 47C8706 A3Z5 ServeRAID M5200 Series RAID 6 Upgrade FoD 1 47C8708 A3Z6 ServeRAID M5200 Series Zer...

Page 18: ...OC controller IBM PowerPC 476 1 2GHz dual core processor The ServeRAID H1110 adapter has the following specifications Four internal 6 Gbps SAS SATA ports One x4 mini SAS internal connector SFF8087 6 G...

Page 19: ...2 A2XD IBM 600GB 10K 6Gbps SAS 2 5 SFF G2HS HDD 26 90Y8877 A2XC IBM 300GB 10K 6Gbps SAS 2 5 SFF G2HS HDD 26 2 5 10K SAS Hot Swap self encrypting drives SEDs 81Y9662 A3EG IBM 900GB 10K 6Gbps SAS 2 5 SF...

Page 20: ...D 16 00W1120 A3HQ IBM 100GB SATA 1 8 MLC Enterprise SSD 16 1 8 solid state drives SSDs Enterprise Value 49Y5993 A3AR IBM 512GB SATA 1 8 MLC Enterprise Value SSD 16 00W1227 A3TH IBM 256GB SATA 1 8 MLC...

Page 21: ...er card options Part number Feature code Description Maximum supported Models where used None A47M x3650 M4 HD PCIe Riser Card 1 1 x16 FH FL 1 x8 FH HL Slots 1 00Y7757 A47Z x3650 M4 HD PCIe Riser Card...

Page 22: ...Riser socket 1 CPU 1 3 PCIe 3 0 x8 FH HL 3 No slot present 3 PCIe 3 0 x16 FH HL 3 PCIe 3 0 x8 FH HL 4 PCIe 3 0 x8 FH FL 4 PCIe 3 0 x16 FH FL 4 PCI X 64b 133 FH FL 4 No slot present 5 PCIe 3 0 x8 FH F...

Page 23: ...llanox ConnectX 3 10 GbE Adapter for IBM System x 6 42C1800 5751 QLogic 10Gb CNA for IBM System x 6 90Y4600 A3MR QLogic 8200 Dual Port 10GbE SFP VFA for IBM System x 6 Gigabit Ethernet 90Y9370 A2V4 Br...

Page 24: ...FC Single port HBA for IBM System x 6 81Y1662 A2W6 Emulex 16Gb FC Dual port HBA for IBM System x 6 00Y3337 A3KW QLogic 16Gb FC Single port HBA for IBM System x 6 00Y3341 A3KX QLogic 16Gb FC Dual port...

Page 25: ...LC Modular Adapter 2 For details about these adapters see the IBM Redbooks Product Guides in the Internal Storage category http www redbooks ibm com portals systemx Open page pg cat internalstorage GP...

Page 26: ...ower supply ships standard with one 2 8 m C13 C14 power cord All IBM CFF power supplies are compliant with and exceed 80 Plus Platinum standard as shown in the following table Maximum power efficiency...

Page 27: ...wer Configurator http ibm com systems bladecenter resources powerconfig html Integrated virtualization The server supports VMware ESXi that is installed on a USB memory key The key is installed in a U...

Page 28: ...an optional console breakout cable that is connected to a port on the front of the server as shown in the following figure Figure 8 Optional console breakout cable The console breakout cable can be or...

Page 29: ...et port at the rear of the server for remote access to the IMM2 Alternatively one of the four Ethernet ports that are accessible by the operating system can be shared with IMM2 access This feature is...

Page 30: ...SP2 Microsoft Windows Server 2008 Datacenter x64 Edition SP2 Microsoft Windows Server 2008 Enterprise x86 Edition SP2 Microsoft Windows Server 2008 Enterprise x64 Edition SP2 Microsoft Windows Server...

Page 31: ...for HDDs Power off Temperature 5 C to 45 C 41 F to 113 F Relative humidity 8 85 Maximum dew point 27 C 80 6 F Storage non operating Temperature 1 C to 60 C 33 8 F to 140 F Altitude 3050 m 10 000 ft R...

Page 32: ...lains warranty service definitions in more detail Table 22 Warranty service definitions Term Description IBM onsite repair IOR A service technician comes to the server s location for equipment repair...

Page 33: ...VMware IBM Director Regulatory compliance The server conforms to the following standards FCC Verified to comply with Part 15 of the FCC Rules Class A Canada ICES 003 issue 5 Class A UL IEC 60950 1 CS...

Page 34: ...rage System 1746A2S IBM System Storage DS3512 Express Single Controller Storage System 1746A4D IBM System Storage DS3524 Express Dual Controller Storage System 1746A4S IBM System Storage DS3524 Expres...

Page 35: ...with cables 44E8869 USB Enclosure Adapter Kit 40K2599 SAS Enclosure Adapter Kit Internal backup drives that are supported by external tape enclosures 46C5364 IBM RDX Removable Hard Disk Storage Syste...

Page 36: ...brary with LTO4 HH SAS drive rack mount kit 3572S5R TS2900 Tape Library with LTO5 HH SAS drive rack mount kit 35732UL TS3100 Tape Library Model L2U Driveless 35734UL TS3200 Tape Library Model L4U Driv...

Page 37: ...with PoE IBM System Networking 10 Gb top of rack switches 7309DRX IBM System Networking RackSwitch G8264CS Rear to Front 7309DFX IBM System Networking RackSwitch G8264CS Front to Rear 7309BD5 IBM Syst...

Page 38: ...20V 53951KX IBM 1500VA LCD 2U Rack UPS 230V 53952AX IBM 2200VA LCD 2U Rack UPS 100V 120V 53952KX IBM 2200VA LCD 2U Rack UPS 230V 53953AX IBM 3000VA LCD 3U Rack UPS 100 V 120 V 53953JX IBM 3000VA LCD 3...

Page 39: ...M4137 IBM 0U 12 C19 12 C13 Switched and Monitored 32A 3 Phase PDU Enterprise PDUs 71762MX IBM Ultra Density Enterprise PDU C19 PDU WW 71762NX IBM Ultra Density Enterprise PDU C19 PDU WW 71763MU IBM Ul...

Page 40: ...Rack PDU with UK LC 39Y8958 DPI Universal Rack PDU with AS NZ LC 39Y8959 DPI Universal Rack PDU with China LC 39Y8962 DPI Universal Rack PDU Argentina 39Y8960 DPI Universal Rack PDU Brazil 39Y8961 DP...

Page 41: ...Rack 93084PX IBM 42U Enterprise Rack 93604EX IBM 42U 1200 mm Deep Dynamic Expansion Rack 93604PX IBM 42U 1200 mm Deep Dynamic Rack 93614EX IBM 42U 1200 mm Deep Static Expansion Rack 93614PX IBM 42U 1...

Page 42: ...C 6695 IBM Global 4x2x32 Console Manager GCM32 1754D1X 1754HC1 FC 6694 IBM Global 2x2x16 Console Manager GCM16 1754A2X 1754HC4 FC 0726 IBM Local 2x16 Console Manager LCM16 1754A1X 1754HC3 FC 0725 IBM...

Page 43: ...now An FMV lease can help you get the solution that you need now with low monthly payments that better align upfront costs with the anticipated return on investment from the technology Easy to acquire...

Page 44: ...age for the x3650 M4 HD http www ibm com systems info x86servers serverproven compat us xseries 5460 html IBM Redbooks Product Guides for IBM System x servers and options http www redbooks ibm com por...

Page 45: ...terials for this IBM product and use of those Web sites is at your own risk IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligat...

Page 46: ...be registered or common law trademarks in other countries A current list of IBM trademarks is available on the Web at http www ibm com legal copytrade shtml The following terms are trademarks of the...

Reviews: