IBM System x3690 X5
22
PCIe SSD adapters
The server supports the High IOPS SSD adapters listed in the following table.
Table 15. High IOPS SSD adapters
Part
number
Feature
code
Description
Maximum
supported
46C9078
A3J3
IBM 365GB High IOPS MLC Mono Adapter
4
46C9081
A3J4
IBM 785GB High IOPS MLC Mono Adapter
4
46M0877
0096
IBM 160GB High IOPS SS Class SSD PCIe Adapter
4
46M0878
0097
IBM 320GB High IOPS SD Class SSD PCIe Adapter
2
46M0898
1649
IBM 320GB High IOPS MS Class SSD PCIe Adapter
4
90Y4377
A3DY
IBM 1.2TB High IOPS MLC Mono Adapter
4
90Y4397
A3DZ
IBM 2.4TB High IOPS MLC Duo Adapter
2
For more information, see the list of IBM Redbooks Product Guides in the Internal Storage category:
http://www.redbooks.ibm.com/portals/systemx?Open&page=pg&cat=internalstorage
Power supplies
The x3690 X5 power subsystem consists of up to four hot-pluggable 675W auto-sensing power supplies.
The modules are independently powered by AC line cords. Most standard models have one or two power
supplies as standard; workload-optimized models have all four standard. An AC power supply ships
standard with one 2.8 m C13 - C14 power cord.
One power supply is sufficient when the total power budget is less than 675W. Use the IBM System x and
BladeCenter® Power Configurator to determine the power requirements of your configuration. The Power
Configurator is available at
http://www.ibm.com/systems/bladecenter/resources/powerconfig.html
For power budgets under 675W, installing a second power supply provides redundancy. To install a
second power supply, use the IBM High Efficiency 675W Power Supply, part number 60Y0332. Installing
four power supplies ensures redundancy even with a fully loaded server. To install the third and fourth
power supplies, use the IBM 675W Redundant Power Supply Kit, part number 60Y0327. The power
subsystem is designed for N+N operation and hot-swap exchange. Having four power supplies installed
allows for N+N redundancy, where N=2 (that is, a total of four power supplies where two are redundant
backups for the other two). The following table lists the part numbers.
The MAX5 V1 has one power supply standard and a second optional power supply for redundancy. See
the MAX5 section for details. The MAX5 V2 has two power supplies installed. No further power supplies
are needed or available.
Table 16. Power supplies
Part number
Feature
code
Description
Maximum
supported
60Y0332
4782
IBM High Efficiency 675W Power Supply
Use for x3690 X5 power supply 2 and MAX5 V1
1 (x3690 X5)
1 (MAX5 V1)
60Y0327
9279
IBM 675W Redundant Power Supply Kit
Use for power supplies 3 and 4.
1