Warranty options

The IBM System x3690 X5 has a 3-year onsite warranty with 9x5/next business day terms. IBM offers the 
warranty service upgrades through IBM ServicePac®, discussed in this section. The IBM ServicePac is a 
series of prepackaged warranty maintenance upgrades and post-warranty maintenance agreements with 
a well-defined scope of services, including service hours, response time, term of service, and service 
agreement terms and conditions.

IBM ServicePac offerings are country-specific, that is, each country might have its own service types, 
service levels, response times, and terms and conditions. Not all covered types of ServicePacs might be 
available in a particular country. For more information about IBM ServicePac offerings available in your 
country visit the IBM ServicePac Product Selector at 

https://www-304.ibm.com/sales/gss/download/spst/servicepac

.

The following table explains warranty service definitions in more detail. 

Table 18. Warranty service definitions

Term

Description

IBM onsite 
repair (IOR)

A service technician will come to the server's location for equipment repair.

24x7x2 hour

A service technician is scheduled to arrive at your customer’s location within two hours after 
remote problem determination is completed. We provide service around the clock, every day, 
including IBM holidays.

24x7x4 hour

A service technician is scheduled to arrive at your customer’s location within four hours after 
remote problem determination is completed. We provide service around the clock, every day, 
including IBM holidays.

9x5x4 hour

A service technician is scheduled to arrive at your customer’s location within four business hours 
after remote problem determination is completed. We provide service from 8:00 a.m. to 5:00 
p.m. in the customer's local time zone, Monday through Friday, excluding IBM holidays. If after 
1:00 p.m. it is determined that onsite service is required, the customer can expect the service 
technician to arrive the morning of the following business day. For noncritical service requests, a 
service technician will arrive by the end of the following business day.

9x5 next 
business day

A service technician is scheduled to arrive at your customer’s location on the business day after 
we receive your call, following remote problem determination. We provide service from 8:00 a.m. 
to 5:00 p.m. in the customer's local time zone, Monday through Friday, excluding IBM holidays.

In general, the types of IBM ServicePacs are as follows:

Warranty and maintenance service upgrades

One, 2, 3, 4, or 5 years of 9x5 or 24x7 service coverage

Onsite repair from next business day to 4 or 2 hours

One or 2 years of warranty extension

Remote technical support services

One or three years with 24x7 coverage (severity 1) or 9x5/next business day for all severities

Installation and startup support for System x servers

Remote technical support for System x servers

Software support - Support Line

Microsoft or Linux software

VMware

IBM Systems Director

Summary of Contents for System x3690 X5

Page 1: ...ach to expanding the system with memory You can first start with 16 DIMMs installed just on the system board then as needs require install the memory mezzanine and an additional 16 DIMMs The for appli...

Page 2: ...y bottlenecks and improve performance Memory access is at up to 1066 MHz frequency depending on the processor model and memory used The MAX5 V2 adds an additional four memory controllers for a total o...

Page 3: ...ics panel and individual light path LEDs quickly lead the technician to failed or failing components which simplifies servicing speeds up problem resolution and helps improve system availability Predi...

Page 4: ...o the same thermal design power TDP limits Low voltage Intel Xeon processors draw less energy to satisfy the demands of power and thermally constrained data centers and telecommunication environments...

Page 5: ...X5 5 Locations of key components and connectors Figure 2 shows the front of the server Figure 2 Front view of the IBM System x3690 X5 Figure 3 shows the rear of the server Figure 3 Rear view of the IB...

Page 6: ...locations of key components inside the server Figure 4 Inside view of the IBM System x3690 X5 Figure 5 shows the MAX5 optional memory expansion unit Figure 5 Inside view of the MAX5 optional memory ex...

Page 7: ...inch NL SAS drives Network interface 2x 1 Gb Ethernet ports based on the Broadcom BCM5709C controller 2x 10 Gb Ethernet ports standard on some models optional on the others 1x Intel Ethernet Quad Port...

Page 8: ...1 4 7147 A2x 1x E7 2820 8C 2 00GHz 18MB 978MHz 105w No support 2x 4GB Optional M1015 4x 2 5 16 Open 2x 1Gb Open 2 4 7147 A3x 1x E7 2830 8C 2 13GHz 24MB 1066MHz 105w Optional 2x 4GB Optional M1015 4x 2...

Page 9: ...4x 10Gb 4 4 Virtualization workload optimized models F1x ESX 2x Xeon E7 2860 10C 2 26GHz 24MB 1066 Std 64x 4GB Std 1x M1015 4x 2 5 16 None 2x 1Gb 2x 10Gb 4 4 F2x RH 2x Xeon E7 2860 10C 2 26GHz 24MB 10...

Page 10: ...KVM The software is not preloaded The model comes standard with the MAX5 memory expansion unit and 256 GB of memory implemented using cost effective 4GB memory DIMMs 128 GB in the server and 128 GB i...

Page 11: ...art number Feature code Description Maximum supported 59Y6265 4199 IBM MAX5 for System x also known as MAX5 V1 1 88Y6529 A19H IBM MAX5 V2 for System x 1 60Y0332 4782 IBM High Efficiency 675W Power Sup...

Page 12: ...DDR3 1066MHz LP RDIMM Yes 32 46C7482 1706 2432 8GB 1x8GB Quad Rankx8 PC3 8500 CL7 ECC DDR3 1066MHz LP RDIMM Yes 32 49Y1400 8939 A1N8 16GB 1x16GB 4Rx4 1 35V PC3L 8500 CL7 ECC DDR3 1066MHz LP RDIMM Yes...

Page 13: ...d in each model are listed in Table 2 Only certain combinations of backplanes are supported see the Installation and User s Guide for information Table 7 Drive backplane options Part number Feature co...

Page 14: ...d state drives SSDs 49Y6139 A3F0 IBM 800GB SAS 2 5 MLC HS Enterprise SSD 16 49Y6134 A3EY IBM 400GB SAS 2 5 MLC HS Enterprise SSD 16 49Y6129 A3EW IBM 200GB SAS 2 5 MLC HS Enterprise SSD 16 00W1125 A3HR...

Page 15: ...B 10K 6Gbps SAS 2 5 SFF G2HS SED 16 44W2264 5413 IBM 300GB 10K 6Gbps SAS 2 5 SFF Slim HS SED 16 90Y8908 A3EF IBM 600GB 10K 6Gbps SAS 2 5 SFF G2HS SED 16 2 5 inch NL SAS hot swap HDDs 81Y9690 A1P3 IBM...

Page 16: ...ntroller either the Advance Feature Key or the Performance Accelerator Key The IBM x3690 X5 RAID Expansion Adapter also known as the ServeRAID Expansion Adapter or IBM 4x4 Drive Backplane ServeRAID Ex...

Page 17: ...48 hours of data retention The ServeRAID M5016 SAS SATA Controller has the following specifications Two Mini SAS internal connectors SFF 8087 Eight internal 6 Gbps SAS SATA ports 6 Gbps throughput pe...

Page 18: ...ltraSlim Enhanced SATA Multi Burner part number 46M0902 supports the following media and speeds for reading CD ROM 24X CD DA DAE 20X CD R 24X CD RW 24X DVD ROM single layer 8X DVD ROM dual layer 8X DV...

Page 19: ...2x8 Riser Card standard in all models All models 60Y0331 9282 IBM System x3690 X5 PCI Express 1x16 Riser Card 3 4 length 60Y0337 9283 IBM System x3690 X5 PCI Express 1x16 Riser Card full length The 1...

Page 20: ...ellanox ConnectX 2 Dual Port 10GbE Adapter for IBM System x 4 00D9690 A3PM Mellanox ConnectX 3 10GbE Adapter for IBM System x 4 42C1800 5751 QLogic 10Gb CNA for IBM System x 4 1 Gb Ethernet 90Y9370 A2...

Page 21: ...cade 8Gb FC Single port HBA for IBM System x 4 42D0494 3581 Emulex 8Gb FC Dual port HBA for IBM System x 4 42D0485 3580 Emulex 8Gb FC Single port HBA for IBM System x 4 42D0510 3579 QLogic 8Gb FC Dual...

Page 22: ...less than 675W Use the IBM System x and BladeCenter Power Configurator to determine the power requirements of your configuration The Power Configurator is available at http www ibm com systems bladece...

Page 23: ...e event log and alerts you to the problem The IMM also provides a virtual presence capability for remote server management capabilities The IMM provides remote server management through industry stand...

Page 24: ...fications Dimensions Height 86 mm 3 5 inches 2U Depth 698 mm 27 4 inches Width 429 mm 16 8 inches Maximum weight 31 3 kg 69 lb when fully configured Electrical 100 to 127 nominal V ac 50 Hz or 60 Hz S...

Page 25: ...rive at your customer s location within four hours after remote problem determination is completed We provide service around the clock every day including IBM holidays 9x5x4 hour A service technician...

Page 26: ...CI Class A IEC 60950 1 2nd edition CB Certificate and CB Test Report Australia and New Zealand C Tick Mark CISPR 22 Class A Taiwan BSMI CNS13438 Class A and CNS14336 China CCC GB4943 2001 GB9254 2008...

Page 27: ...nclosures Table 20 Hard drive options for external expansion enclosures Part number Description Maximum quantity supported per one enclosure SATA Hot Swap HDDs IBM 500GB 7200 SATA 2 5 SFF Slim HS HDD...

Page 28: ...Accelerator Key 6 Gbps throughput per port PCI Express 2 0 x8 host interface Based on the LSI SAS2108 6 Gbps ROC controller 512 MB of onboard cache Intelligent Li Ion based battery backup unit with up...

Page 29: ...s Dual Controller Storage System 1746A2S IBM System Storage DS3512 Express Single Controller Storage System 1746A4D IBM System Storage DS3524 Express Dual Controller Storage System 1746A4S IBM System...

Page 30: ...ith cables 44E8869 USB Enclosure Adapter Kit 40K2599 SAS Enclosure Adapter Kit Internal backup drives supported by external tape enclosures 46C5364 IBM RDX Removable Hard Disk Storage System Internal...

Page 31: ...ge TS2250 Tape Drive Express Model H5S 3580S5X System Storage TS2350 Tape Drive Express Model S53 3572S4R TS2900 Tape Library with LTO4 HH SAS drive rack mount kit 3572S5R TS2900 Tape Library with LTO...

Page 32: ...oE IBM System Networking 10 Gb top of rack switches 7309DRX IBM System Networking RackSwitch G8264CS Rear to Front 7309DFX IBM System Networking RackSwitch G8264CS Front to Rear 7309BD5 IBM System Net...

Page 33: ...units Part number Description 21303RX IBM UPS 7500XHV 21304RX IBM UPS 10000XHV 24195KX IBM UPS5000 HV 53956AX IBM 6000VA LCD 4U Rack UPS 200V 208V 53956KX IBM 6000VA LCD 4U Rack UPS 230V 53959KX IBM 1...

Page 34: ...Front end PDU with NEMA L6 30P 39Y8940 DPI 60amp 250V Front end PDU with IEC 309 2P Gnd connector 39Y8941 IBM Enterprise C13 PDU 39Y8948 IBM Enterprise C19 PDU 71762MX IBM Ultra Density Enterprise C19...

Page 35: ...2U Enterprise Expansion Rack 93084PX IBM 42U Enterprise Rack 99564RX IBM S2 42U Dynamic Standard Rack Cabinet 99564XX IBM S2 42U Dynamic Expansion Rack Cabinet 93604PX 42U Deep Dynamic Primary Cabinet...

Page 36: ...Available cable management arms are also listed Table 29 Rail kit options and cable management arms Part number Feature code Description Use Rail kits 69Y2345 4786 IBM System x3690 X5 Ball Bearing Sl...

Page 37: ...72317X 1U 17in Flat Panel Console Kit 172319X 1U 19in Flat Panel Console Kit 17352GX IBM Global 2x16 Console Mngr GCM2 1754D1X IBM Global 2X2X16 Console Manager 1754D2X IBM Global 4X2X32 Console Manag...

Page 38: ...w An FMV lease can help you get the solution you need now with low monthly payments that better align upfront costs with the anticipated return on investment from the technology Easy to acquire with a...

Page 39: ...t entry portal docdisplay lndocid MIGR 5085206 IBM System x3690 X5 Problem Determination and Service Guide http ibm com support entry portal docdisplay lndocid MIGR 5085205 ServerProven hardware compa...

Page 40: ...erials for this IBM product and use of those Web sites is at your own risk IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligati...

Page 41: ...ublished Such trademarks may also be registered or common law trademarks in other countries A current list of IBM trademarks is available on the Web at http www ibm com legal copytrade shtml The follo...

Reviews: