Table 10. System x3690 X5 IMM error messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v
See Chapter 4, “Parts listing, System x3690 X5 Types 7147, 7148, 7149, and 7192,” on page 249 to determine which components
are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service
technician.
Event ID
Message
Severity
Description
Action
80010902-0701xxxx
Numeric sensor Planar 3.3V going
high (upper critical) has asserted.
Error
An upper critical
sensor going high
has asserted.
(Trained service technician
only) Replace the system
board.
80010902-0701xxxx
Numeric sensor Planar 5V going high
(upper critical) has asserted.
Error
An upper critical
sensor going high
has asserted.
(Trained service technician
only) Replace the system
board.
80010903-1501xxxx
Numeric sensor FG 1PS going high
(upper critical) has asserted.
Warning
Power supply fuel
gage warning.
1.
The management
controller has detected a
sensor transitioned to
critical from less severe
on the power supply 1.
2.
Make sure that the
power supply is
installed correctly (see
“Replacing a hot-swap
power supply” on page
326) . Make sure that no
error LEDs are lit on the
power supply and that
all power supplies have
the green LEDs lit.
80010903-1502xxxx
Numeric sensor FG 2PS going high
(upper critical) has asserted.
Warning
Power supply fuel
gage warning.
1.
The management
controller has detected a
sensor transitioned to
critical from less severe
on the power supply 2.
2.
Make sure that the
power supply is
installed correctly (see
“Replacing a hot-swap
power supply” on page
326). Make sure that no
error LEDs are lit on the
power supply and that
all power supplies have
the green LEDs lit.
80010903-1503xxxx
Numeric sensor FG 3PS going high
(upper critical) has asserted.
Warning
Power supply fuel
gage warning.
1.
The management
controller has detected a
sensor transitioned to
critical from less severe
on the power supply 3.
2.
Make sure that the
power supply is
installed correctly (see
“Replacing a hot-swap
power supply” on page
326). Make sure that no
error LEDs are lit on the
power supply and that
all power supplies have
the green LEDs lit.
170
System x3690 X5 Types 7147, 7148, 7149, and 7192: Problem Determination and Service Guide
Summary of Contents for System x3690 X5
Page 1: ...System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 8: ...vi System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 13: ...Safety statements Safety xi...
Page 22: ...4 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 266: ...248 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 278: ...260 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 386: ...368 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 407: ...1 2 Chapter 5 Removing and replacing components 389...
Page 444: ...426 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 454: ...436 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 461: ...weight of memory enclosure 28 Index 443...
Page 462: ...444 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 463: ......
Page 464: ...Part Number 47C8865 Printed in USA 1P P N 47C8865...