Table 10. System x3690 X5 IMM error messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v
See Chapter 4, “Parts listing, System x3690 X5 Types 7147, 7148, 7149, and 7192,” on page 249 to determine which components
are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service
technician.
Event ID
Message
Severity
Description
Action
80070219-0701xxxx
Sensor Sys Board Fault has
transitioned to critical from a less
severe state.
Error
A sensor has
changed to Critical
state from a less
severe state.
1.
Check the system-event
log.
2.
Check for an error LED
on the system board.
3.
Replace any failing
device.
4.
Check for a server
firmware update.
Important:
Some cluster
solutions require
specific code levels or
coordinated code
updates. If the device is
part of a cluster
solution, verify that the
latest level of code is
supported for the
cluster solution before
you update the code.
5.
(Trained service
technician only) Replace
the system board.
8007021b-0301xxxx
Sensor Int QPI Link 1 : has
transitioned to critical from a less
severe state.
Warning
The management
controller has
detected a Sensor
transitioned to
critical from less
severe.
1.
Check the system-event
log in the UEFI F1
Setup Utility screen.
2.
Check the
microprocessor error
LEDs.
3.
(Trained service
technician only) Remove
the failing
microprocessor (see
“Removing a
microprocessor and heat
sink” on page 349 and
“Replacing a
microprocessor and heat
sink” on page 351).
4.
Check for a UEFI,
FPGA, and IMM
firmware update (see
“Updating the
firmware” on page 397
for information on
updating the firmware).
5.
Make sure that the
microprocessors are
matching.
6.
(Trained service
technician only) Replace
the system board.
176
System x3690 X5 Types 7147, 7148, 7149, and 7192: Problem Determination and Service Guide
Summary of Contents for System x3690 X5
Page 1: ...System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 8: ...vi System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 13: ...Safety statements Safety xi...
Page 22: ...4 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 266: ...248 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 278: ...260 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 386: ...368 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 407: ...1 2 Chapter 5 Removing and replacing components 389...
Page 444: ...426 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 454: ...436 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 461: ...weight of memory enclosure 28 Index 443...
Page 462: ...444 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 463: ......
Page 464: ...Part Number 47C8865 Printed in USA 1P P N 47C8865...