Table 10. System x3690 X5 IMM error messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v
See Chapter 4, “Parts listing, System x3690 X5 Types 7147, 7148, 7149, and 7192,” on page 249 to determine which components
are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service
technician.
Event ID
Message
Severity
Description
Action
Sensor PS
n
CSF has deasserted the
transition to non-recoverable (
n
=
power supply number)
Info
Power supply
n
is
normal.
No action; informational
only.
Sensor PS
n
CSF has transitioned to
non-recoverable (
n
= power supply
number)
Error
An error has been
detected for Power
supply
n
.
1.
Check the power supply
LEDs.
2.
Check for power supply
mismatch.
3.
Reseat the power
supply.
4.
Replace the power
supply
Sensor PS
n
has transitioned to a less
severe state from critical (
n
= power
supply number)
Info
Power supply
n
is
normal.
No action; informational
only.
Sensor PS
n
has transitioned to a
critical from a less severe state (
n
=
power supply number)
Error
An error has been
detected for Power
supply
n
.
1.
Check the power supply
LEDs.
2.
Check the power supply
fan.
3.
Reseat the power
supply.
4.
Replace the power
supply
80070608-140axxxx
Sensor IOH 1.1V VRD has
transitioned to non-recoverable
Error
A VRD error is
detected.
(Trained service technician
only) Replace the system
board.
80070608-140bxxxx
Sensor IOH 1.5V VRD has
transitioned to non-recoverable
Error
A VRD error is
detected.
(Trained service technician
only) Replace the system
board.
80070608-140cxxxx
Sensor IOH 1.8V VRD has
transitioned to non-recoverable
Error
A VRD error is
detected.
(Trained service technician
only) Replace the system
board.
80070608-140cxxxx
Sensor CPU_1_8V_PG has transitioned
to non-recoverable
Error
(Trained service technician
only) Replace the system
board.
80070618-0701xxxx
Sensor VT Fault has transitioned to
non-recoverable.
Error
A sensor has
changed to
Nonrecoverable
state.
1.
Check the power-supply
LEDs.
2.
Follow the actions in
“Power-supply LEDs”
on page 78 and “Power
problems” on page 62.
3.
Replace the failing
power supply.
4.
(Trained service
technician only) Replace
the system board.
Chapter 3. Diagnostics
181
Summary of Contents for System x3690 X5
Page 1: ...System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 8: ...vi System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 13: ...Safety statements Safety xi...
Page 22: ...4 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 266: ...248 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 278: ...260 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 386: ...368 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 407: ...1 2 Chapter 5 Removing and replacing components 389...
Page 444: ...426 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 454: ...436 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 461: ...weight of memory enclosure 28 Index 443...
Page 462: ...444 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 463: ......
Page 464: ...Part Number 47C8865 Printed in USA 1P P N 47C8865...